Unknown

Dataset Information

0

The accuracy of emergency weight estimation systems in children-a systematic review and meta-analysis.


ABSTRACT: The safe and effective administration of fluids and medications during the management of medical emergencies in children depends on an appropriately determined dose, based on body weight. Weight can often not be measured in these circumstances and a convenient, quick and accurate method of weight estimation is required. Most methods in current use are not accurate enough, but the newer length-based, habitus-modified (two-dimensional) systems have shown significantly higher accuracy. This meta-analysis evaluated the accuracy of weight estimation systems in children. Articles were screened for inclusion into two study arms: to determine an appropriate accuracy target for weight estimation systems; and to evaluate the accuracy of existing systems using standard meta-analysis techniques. There was no evidence found to support any specific goal of accuracy. Based on the findings of this study, a proposed minimum accuracy of 70% of estimations within 10% of actual weight (PW10 > 70%), and 95% within 20% of actual weight (PW20 > 95%) should be demonstrated by a weight estimation system before being considered to be accurate. In the meta-analysis, the two-dimensional systems performed best. The Mercy method (PW10 70.9%, PW20 95.3%), the PAWPER tape (PW10 78.0%, PW20 96.6%) and parental estimates (PW10 69.8%, PW20 87.1%) were the most accurate systems investigated, with the Broselow tape (PW10 55.6%, PW20 81.2%) achieving a lesser accuracy. Age-based estimates achieved a very low accuracy. Age- and length-based systems had a substantial difference in over- and underestimation of weight in high-income and low- and middle-income populations. A benchmark for minimum accuracy is recommended for weight estimation studies and a PW10 > 70% with PW20 > 95% is suggested. The Mercy method, the PAWPER tape and parental estimates were the most accurate weight estimation systems followed by length-based and age-based systems. The use of age-based formulas should be abandoned because of their poor accuracy.

SUBMITTER: Wells M 

PROVIDER: S-EPMC5608658 | biostudies-literature | 2017 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

The accuracy of emergency weight estimation systems in children-a systematic review and meta-analysis.

Wells Mike M   Goldstein Lara Nicole LN   Bentley Alison A  

International journal of emergency medicine 20170921 1


The safe and effective administration of fluids and medications during the management of medical emergencies in children depends on an appropriately determined dose, based on body weight. Weight can often not be measured in these circumstances and a convenient, quick and accurate method of weight estimation is required. Most methods in current use are not accurate enough, but the newer length-based, habitus-modified (two-dimensional) systems have shown significantly higher accuracy. This meta-an  ...[more]

Similar Datasets

| S-EPMC6246873 | biostudies-literature
| S-EPMC6549628 | biostudies-literature
| S-EPMC3778861 | biostudies-other
| S-EPMC7390574 | biostudies-literature
| S-EPMC6302883 | biostudies-other
| S-EPMC10787364 | biostudies-literature
| 79216 | ecrin-mdr-crc
| S-EPMC5045959 | biostudies-other
| S-EPMC7860950 | biostudies-literature
| S-EPMC10788842 | biostudies-literature