Unknown

Dataset Information

0

Affective Stimuli for an Auditory P300 Brain-Computer Interface.


ABSTRACT: Gaze-independent brain computer interfaces (BCIs) are a potential communication tool for persons with paralysis. This study applies affective auditory stimuli to investigate their effects using a P300 BCI. Fifteen able-bodied participants operated the P300 BCI, with positive and negative affective sounds (PA: a meowing cat sound, NA: a screaming cat sound). Permuted stimuli of the positive and negative affective sounds (permuted-PA, permuted-NA) were also used for comparison. Electroencephalography data was collected, and offline classification accuracies were compared. We used a visual analog scale (VAS) to measure positive and negative affective feelings in the participants. The mean classification accuracies were 84.7% for PA and 67.3% for permuted-PA, while the VAS scores were 58.5 for PA and -12.1 for permuted-PA. The positive affective stimulus showed significantly higher accuracy and VAS scores than the negative affective stimulus. In contrast, mean classification accuracies were 77.3% for NA and 76.0% for permuted-NA, while the VAS scores were -50.0 for NA and -39.2 for permuted NA, which are not significantly different. We determined that a positive affective stimulus with accompanying positive affective feelings significantly improved BCI accuracy. Additionally, an ALS patient achieved 90% online classification accuracy. These results suggest that affective stimuli may be useful for preparing a practical auditory BCI system for patients with disabilities.

SUBMITTER: Onishi A 

PROVIDER: S-EPMC5613193 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

Affective Stimuli for an Auditory P300 Brain-Computer Interface.

Onishi Akinari A   Takano Kouji K   Kawase Toshihiro T   Ora Hiroki H   Kansaku Kenji K  

Frontiers in neuroscience 20170921


Gaze-independent brain computer interfaces (BCIs) are a potential communication tool for persons with paralysis. This study applies affective auditory stimuli to investigate their effects using a P300 BCI. Fifteen able-bodied participants operated the P300 BCI, with positive and negative affective sounds (PA: a meowing cat sound, NA: a screaming cat sound). Permuted stimuli of the positive and negative affective sounds (permuted-PA, permuted-NA) were also used for comparison. Electroencephalogra  ...[more]

Similar Datasets

| S-EPMC5670086 | biostudies-literature
| S-EPMC4456572 | biostudies-literature
| S-EPMC8709057 | biostudies-literature
| S-EPMC5587109 | biostudies-literature
| S-EPMC4288388 | biostudies-literature
| S-EPMC7987063 | biostudies-literature
| S-EPMC4041754 | biostudies-literature
| S-EPMC3482251 | biostudies-other
| S-EPMC6390079 | biostudies-literature