The accuracy of postoperative, non-invasive Air-Test to diagnose atelectasis in healthy patients after surgery: a prospective, diagnostic pilot study.


ABSTRACT: OBJECTIVE:To assess the diagnostic accuracy of peripheral capillary oxygen saturation (SpO2) while breathing room air for 5 min (the 'Air-Test') in detecting postoperative atelectasis. DESIGN:Prospective cohort study. Diagnostic accuracy was assessed by measuring the agreement between the index test and the reference standard CT scan images. SETTING:Postanaesthetic care unit in a tertiary hospital in Spain. PARTICIPANTS:Three hundred and fifty patients from 12 January to 7 February 2015; 170 patients scheduled for surgery under general anaesthesia who were admitted into the postsurgical unit were included. INTERVENTION:The Air-Test was performed in conscious extubated patients after a 30 min stabilisation period during which they received supplemental oxygen therapy via a venturi mask. The Air-Test was defined as positive when SpO2 was ?96% and negative when SpO2 was ?97%. Arterial blood gases were measured in all patients at the end of the Air-Test. In the subsequent 25 min, the presence of atelectasis was evaluated by performing a CT scan in 59 randomly selected patients. MAIN OUTCOME MEASURES:The primary study outcome was assessment of the accuracy of the Air-Test for detecting postoperative atelectasis compared with the reference standard. The secondary outcome was the incidence of positive Air-Test results. RESULTS:The Air-Test diagnosed postoperative atelectasis with an area under the receiver operating characteristic curve of 0.90 (95% CI 0.82 to 0.98) with a sensitivity of 82.6% and a specificity of 87.8%. The presence of atelectasis was confirmed by CT scans in all patients (30/30) with positive and in 5 patients (17%) with negative Air-Test results. Based on the Air-Test, postoperative atelectasis was present in 36% of the patients (62 out of 170). CONCLUSION:The Air-Test may represent an accurate, simple, inexpensive and non-invasive method for diagnosing postoperative atelectasis. TRIAL REGISTRATION:NCT02650037.

SUBMITTER: Ferrando C 

PROVIDER: S-EPMC5623366 | biostudies-literature | 2017 May

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Objective</h4>To assess the diagnostic accuracy of peripheral capillary oxygen saturation (SpO<sub>2</sub>) while breathing room air for 5 min (the 'Air-Test') in detecting postoperative atelectasis.<h4>Design</h4>Prospective cohort study. Diagnostic accuracy was assessed by measuring the agreement between the index test and the reference standard CT scan images.<h4>Setting</h4>Postanaesthetic care unit in a tertiary hospital in Spain.<h4>Participants</h4>Three hundred and fifty patients fro  ...[more]

Similar Datasets

| S-EPMC7576699 | biostudies-literature
| S-EPMC8353091 | biostudies-literature
| S-EPMC3851548 | biostudies-literature
| S-EPMC3444439 | biostudies-other
| S-EPMC6545496 | biostudies-literature
| S-EPMC6470197 | biostudies-literature
| S-EPMC2890997 | biostudies-literature
| S-EPMC7404380 | biostudies-literature
| S-EPMC4184363 | biostudies-literature
| S-EPMC7723495 | biostudies-literature