Next Generation Flow for highly sensitive and standardized detection of minimal residual disease in multiple myeloma.


ABSTRACT: Flow cytometry has become a highly valuable method to monitor minimal residual disease (MRD) and evaluate the depth of complete response (CR) in bone marrow (BM) of multiple myeloma (MM) after therapy. However, current flow-MRD has lower sensitivity than molecular methods and lacks standardization. Here we report on a novel next generation flow (NGF) approach for highly sensitive and standardized MRD detection in MM. An optimized 2-tube 8-color antibody panel was constructed in five cycles of design-evaluation-redesign. In addition, a bulk-lysis procedure was established for acquisition of ?107 cells/sample, and novel software tools were constructed for automatic plasma cell gating. Multicenter evaluation of 110 follow-up BM from MM patients in very good partial response (VGPR) or CR showed a higher sensitivity for NGF-MRD vs conventional 8-color flow-MRD -MRD-positive rate of 47 vs 34% (P=0.003)-. Thus, 25% of patients classified as MRD-negative by conventional 8-color flow were MRD-positive by NGF, translating into a significantly longer progression-free survival for MRD-negative vs MRD-positive CR patients by NGF (75% progression-free survival not reached vs 7 months; P=0.02). This study establishes EuroFlow-based NGF as a highly sensitive, fully standardized approach for MRD detection in MM which overcomes the major limitations of conventional flow-MRD methods and is ready for implementation in routine diagnostics.

SUBMITTER: Flores-Montero J 

PROVIDER: S-EPMC5629369 | biostudies-literature | 2017 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications


Flow cytometry has become a highly valuable method to monitor minimal residual disease (MRD) and evaluate the depth of complete response (CR) in bone marrow (BM) of multiple myeloma (MM) after therapy. However, current flow-MRD has lower sensitivity than molecular methods and lacks standardization. Here we report on a novel next generation flow (NGF) approach for highly sensitive and standardized MRD detection in MM. An optimized 2-tube 8-color antibody panel was constructed in five cycles of de  ...[more]

Similar Datasets

| S-EPMC7603393 | biostudies-literature
| S-EPMC10951185 | biostudies-literature
| S-EPMC9175670 | biostudies-literature
| S-EPMC9928796 | biostudies-literature
| S-EPMC6924563 | biostudies-literature
| S-EPMC7878533 | biostudies-literature
| S-EPMC9426755 | biostudies-literature
| S-EPMC8515655 | biostudies-literature
| S-EPMC7874334 | biostudies-literature
| S-EPMC8791109 | biostudies-literature