Effect of inspiratory synchronization during pressure-controlled ventilation on lung distension and inspiratory effort.


ABSTRACT: BACKGROUND:In pressure-controlled (PC) ventilation, tidal volume (V T) and transpulmonary pressure (P L ) result from the addition of ventilator pressure and the patient's inspiratory effort. PC modes can be classified into fully, partially, and non-synchronized modes, and the degree of synchronization may result in different V T and P L despite identical ventilator settings. This study assessed the effects of three PC modes on V T, P L , inspiratory effort (esophageal pressure-time product, PTPes), and airway occlusion pressure, P 0.1. We also assessed whether P 0.1 can be used for evaluating patient effort. METHODS:Prospective, randomized, crossover physiologic study performed in 14 spontaneously breathing mechanically ventilated patients recovering from acute respiratory failure (1 subsequently withdrew). PC modes were fully (PC-CMV), partially (PC-SIMV), and non-synchronized (PC-IMV using airway pressure release ventilation) and were applied randomly; driving pressure, inspiratory time, and set respiratory rate being similar for all modes. Airway, esophageal pressure, P 0.1, airflow, gas exchange, and hemodynamics were recorded. RESULTS:V T was significantly lower during PC-IMV as compared with PC-SIMV and PC-CMV (387 ± 105 vs 458 ± 134 vs 482 ± 108 mL, respectively; p < 0.05). Maximal P L was also significantly lower (13.3 ± 4.9 vs 15.3 ± 5.7 vs 15.5 ± 5.2 cmH2O, respectively; p < 0.05), but PTPes was significantly higher in PC-IMV (215.6 ± 154.3 vs 150.0 ± 102.4 vs 130.9 ± 101.8 cmH2O × s × min-1, respectively; p < 0.05), with no differences in gas exchange and hemodynamic variables. PTPes increased by more than 15% in 10 patients and by more than 50% in 5 patients. An increased P 0.1 could identify high levels of PTPes. CONCLUSIONS:Non-synchronized PC mode lowers V T and P L in comparison with more synchronized modes in spontaneously breathing patients but can increase patient effort and may need specific adjustments. Clinical Trial Registration Clinicaltrial.gov # NCT02071277.

SUBMITTER: Rittayamai N 

PROVIDER: S-EPMC5630544 | biostudies-literature | 2017 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Effect of inspiratory synchronization during pressure-controlled ventilation on lung distension and inspiratory effort.

Rittayamai Nuttapol N   Beloncle François F   Goligher Ewan C EC   Chen Lu L   Mancebo Jordi J   Richard Jean-Christophe M JM   Brochard Laurent L  

Annals of intensive care 20171006 1


<h4>Background</h4>In pressure-controlled (PC) ventilation, tidal volume (V <sub>T</sub>) and transpulmonary pressure (P <sub>L</sub> ) result from the addition of ventilator pressure and the patient's inspiratory effort. PC modes can be classified into fully, partially, and non-synchronized modes, and the degree of synchronization may result in different V <sub>T</sub> and P <sub>L</sub> despite identical ventilator settings. This study assessed the effects of three PC modes on V <sub>T</sub>,  ...[more]

Similar Datasets

| S-EPMC9510081 | biostudies-literature
| S-EPMC8708509 | biostudies-literature
| S-EPMC8672539 | biostudies-literature
| S-EPMC8182360 | biostudies-literature
| S-EPMC10643759 | biostudies-literature
| S-EPMC7908005 | biostudies-literature
| S-EPMC5007729 | biostudies-other
| S-EPMC9958297 | biostudies-literature
| S-EPMC8797006 | biostudies-literature
| S-EPMC7092676 | biostudies-literature