Added value of gadoxetic acid-enhanced T1-weighted magnetic resonance cholangiography for the diagnosis of post-transplant biliary complications.


ABSTRACT: OBJECTIVES:Biliary complications after liver transplantation (LT) are common. This study aimed to ascertain the value of gadoxetic acid-enhanced T1-weighted (T1w) magnetic resonance cholangiography (MRC) to evaluate anastomotic strictures (AS), non-anastomotic strictures (NAS) and biliary casts (BC). METHODS:Sixty liver-transplanted patients with suspicion of biliary complications and T2w-MRCP and T1w-MRC followed by endoscopic retrograde cholangiopancreatography (ERCP) or percutaneous transhepatic cholangiography (PTC) were analysed. Two readers reviewed the MRCs and rated image quality (IQ) and likelihood for AS/NAS/BC on Likert scales. Sensitivity, specificity and predictive values were calculated, ROC curve analysis performed, and inter-reader variability assessed. The subjective added value of T1w-MRC was rated. RESULTS:IQ was high for all sequences without significant differences (2.83-2.88). In 39 patients ERCP/PTC detected a complication. Sensitivity and specificity for AS were 64-96 using T2w-MRCP, increasing to 79-100 using all sequences. Use of all sequences increased the sensitivity of detecting NAS/BC from 72-92% to 88-100% and 67-89% to 72-94%, respectively. Kappa values were substantial (0.45-0.62). T1w-MRC was found to be helpful in 75-83.3%. CONCLUSIONS:Combining T1w-MRC and T2w-MRCP increased sensitivity and specificity and diagnostic confidence in patients after LT with suspected biliary complications. T1w-MRC is a valuable tool for evaluating post-transplant biliary complications. KEY POINTS:• T1w-MRC is a valuable tool for evaluating post-transplant biliary complications. • Adding T1w-MRC to T2w-MRC increases diagnostic confidence for detection of biliary complications. • A combination of T1w-MRC and T2w-MRCP leads to the best results.

SUBMITTER: Kinner S 

PROVIDER: S-EPMC5640478 | biostudies-literature | 2017 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Added value of gadoxetic acid-enhanced T1-weighted magnetic resonance cholangiography for the diagnosis of post-transplant biliary complications.

Kinner Sonja S   Schubert Tilman B TB   Said Adnan A   Mezrich Joshua D JD   Reeder Scott B SB  

European radiology 20170413 10


<h4>Objectives</h4>Biliary complications after liver transplantation (LT) are common. This study aimed to ascertain the value of gadoxetic acid-enhanced T1-weighted (T1w) magnetic resonance cholangiography (MRC) to evaluate anastomotic strictures (AS), non-anastomotic strictures (NAS) and biliary casts (BC).<h4>Methods</h4>Sixty liver-transplanted patients with suspicion of biliary complications and T2w-MRCP and T1w-MRC followed by endoscopic retrograde cholangiopancreatography (ERCP) or percuta  ...[more]

Similar Datasets

| S-EPMC9388415 | biostudies-literature
| S-EPMC7167323 | biostudies-literature
| S-EPMC4334264 | biostudies-literature
| S-EPMC7189724 | biostudies-literature
| S-EPMC8257540 | biostudies-literature
| S-EPMC7722597 | biostudies-literature
| S-EPMC4614056 | biostudies-other
| S-EPMC4500813 | biostudies-literature
| S-EPMC5045863 | biostudies-literature
| S-EPMC10788609 | biostudies-literature