Performance and consistency of a fluorescence-based high-throughput screening assay for use in Babesia drug screening in mice.


ABSTRACT: In this study, we evaluated the validity of a fluorescence-based assay using SYBR Green I (SG I) stain for screening antibabesial compounds against B. microti in mice. Two different hematocrits (HCTs; 2.5% and 5%) were used. Correlating relative fluorescence units (RFUs) with parasitemia showed significant linear relationships with R2 values of 0.97 and 0.99 at HCTs of 2.5% and 5%, respectively. Meanwhile, the Z' factors in a high-throughput screening (HTS) assay were within the permissible limit (?0.5) at 2.5% HCT and lower than this value at 5% HCT. Taken together, the highest signal-to-noise (S/N) ratios were obtained at 2.5% HCT; therefore, we concluded that 2.5% was the best HCT for applying fluorescence assay in antibabesial drug screening in mice. Additionally, positive control mice and those treated with diminazene aceturate, pyronaridine tetraphosphate, and an allicin/diminazene aceturate combination showed peak parasitemia and fluorescence values on the same day post-inoculation. Moreover, using different concentrations of SG I revealed that the optimal concentration was 2x. In summary, considering that all experiments were applied under optimal laboratory conditions, fluorescence assay at 2.5% HCT using 2x SG I for B. microti parasite offers a novel approach for drug screening in mice.

SUBMITTER: Rizk MA 

PROVIDER: S-EPMC5643553 | biostudies-literature | 2017 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Performance and consistency of a fluorescence-based high-throughput screening assay for use in Babesia drug screening in mice.

Rizk Mohamed Abdo MA   El-Sayed Shimaa Abd El-Salam SAE   AbouLaila Mahmoud M   Eltaysh Rasha R   Yokoyama Naoaki N   Igarashi Ikuo I  

Scientific reports 20171016 1


In this study, we evaluated the validity of a fluorescence-based assay using SYBR Green I (SG I) stain for screening antibabesial compounds against B. microti in mice. Two different hematocrits (HCTs; 2.5% and 5%) were used. Correlating relative fluorescence units (RFUs) with parasitemia showed significant linear relationships with R<sup>2</sup> values of 0.97 and 0.99 at HCTs of 2.5% and 5%, respectively. Meanwhile, the Z' factors in a high-throughput screening (HTS) assay were within the permi  ...[more]

Similar Datasets

| S-EPMC4411034 | biostudies-literature
| S-EPMC3530442 | biostudies-literature
| S-EPMC10507874 | biostudies-literature
| S-EPMC3774111 | biostudies-literature
| S-EPMC5563979 | biostudies-literature
| S-EPMC4677366 | biostudies-literature
| S-EPMC8458687 | biostudies-literature
| S-EPMC6445550 | biostudies-literature
| S-EPMC3152590 | biostudies-literature
| S-EPMC6062809 | biostudies-other