Unknown

Dataset Information

0

Handheld Photoacoustic Microscopy Probe.


ABSTRACT: Optical resolution photoacoustic microscopy (OR-PAM) is a non-invasive, label-free method of in vivo imaging with microscopic resolution and high optical contrast. Based on intrinsic contrasts, OR-PAM has expanded to include in vivo vessel imaging, flow cytometry, physiological parameter analysis, and single-cell characterization. However, since conventional OR-PAM systems have a fixed tabletop configuration, a large system size, and slow imaging speed, their use in preclinical and clinical studies remains limited. In this study, using microelectromechanical systems (MEMS) technology, we developed a handheld PAM probe with a high signal-to-noise ratio and image rate. To enable broader application of the OR-PAM system, we reduced its size and combined its fast scanning capabilities into a small handheld probe that uses a 2-axis waterproof MEMS scanner (2A-WP-MEMS scanner). All acoustical, optical, and mechanical components are integrated into a single probe with a diameter of 17?mm and a weight of 162?g. This study shows phantom and in vivo images of various samples acquired with the probe, including carbon fibers, electrospun microfibers, and the ear, iris, and brain of a living mouse. In particular, this study investigated the possibility of clinical applications for melanoma diagnosis by imaging the boundaries and morphology of a human mole.

SUBMITTER: Park K 

PROVIDER: S-EPMC5645466 | biostudies-literature | 2017 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Handheld Photoacoustic Microscopy Probe.

Park Kyungjin K   Kim Jin Young JY   Lee Changho C   Jeon Seungwan S   Lim Geunbae G   Kim Chulhong C  

Scientific reports 20171017 1


Optical resolution photoacoustic microscopy (OR-PAM) is a non-invasive, label-free method of in vivo imaging with microscopic resolution and high optical contrast. Based on intrinsic contrasts, OR-PAM has expanded to include in vivo vessel imaging, flow cytometry, physiological parameter analysis, and single-cell characterization. However, since conventional OR-PAM systems have a fixed tabletop configuration, a large system size, and slow imaging speed, their use in preclinical and clinical stud  ...[more]

Similar Datasets

| S-EPMC7726342 | biostudies-literature
| S-EPMC7090348 | biostudies-literature
| S-EPMC4287460 | biostudies-literature
| S-EPMC4021812 | biostudies-other
| S-EPMC6688948 | biostudies-literature
| S-EPMC3289054 | biostudies-other
| S-EPMC3651204 | biostudies-other
| S-EPMC8018531 | biostudies-literature
| S-EPMC8292735 | biostudies-literature
| S-EPMC6401249 | biostudies-literature