Unknown

Dataset Information

0

A case report of lung ultrasound missing a pneumothorax due to patient positioning.


ABSTRACT: Lung ultrasound is increasingly utilized as a diagnostic tool for the detection of a pneumothorax. The effect of small changes in patient positioning on the accuracy of lung ultrasound to detect a pneumothorax is not well studied. We present the first known case of lung ultrasound missing a pneumothorax because of suboptimal patient positioning, and discuss the implications of our findings for clinicians that utilize lung ultrasound and for future research.

SUBMITTER: Schrift D 

PROVIDER: S-EPMC5676526 | biostudies-literature | 2017 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

A case report of lung ultrasound missing a pneumothorax due to patient positioning.

Schrift David D   Barron Keith K   Wagner Michael M   Arya Rohan R  

Ultrasound (Leeds, England) 20170525 4


Lung ultrasound is increasingly utilized as a diagnostic tool for the detection of a pneumothorax. The effect of small changes in patient positioning on the accuracy of lung ultrasound to detect a pneumothorax is not well studied. We present the first known case of lung ultrasound missing a pneumothorax because of suboptimal patient positioning, and discuss the implications of our findings for clinicians that utilize lung ultrasound and for future research. ...[more]

Similar Datasets

| S-EPMC4360687 | biostudies-other
| S-EPMC5548950 | biostudies-other
| S-EPMC7301769 | biostudies-literature
| S-EPMC4904536 | biostudies-literature
| S-EPMC6114535 | biostudies-literature
| S-EPMC3923561 | biostudies-literature
| S-EPMC6862922 | biostudies-literature
| S-EPMC6148831 | biostudies-literature
| S-EPMC8177981 | biostudies-literature
| S-EPMC7607218 | biostudies-literature