Unknown

Dataset Information

0

Minimally Invasive Hemostatic Materials: Tackling a Dilemma of Fluidity and Adhesion by Photopolymerization in situ.


ABSTRACT: Hemostasis in vivo is a key to success in minimally invasive surgery (MIS). However, solid hemostatic materials cannot pass through the sheath tube of the MIS apparatus, while liquid ones are restricted by their low adhesion, which leads to them peeling off of tissue. To tackle the dilemma of fluidity and adhesion, a formulation containing a multifunctional sucrose allyl ether (SAE) monomer and an alpha-hydroxyketone liquid photoinitiator (HMPP) was applied as a lead hemostatic material for MIS. Real-time infrared results showed that SAE initiated by HMPP can rapidly polymerize into a transparent crosslinking membrane. Quantum chemistry showed that this occurs via a free radical addition reaction mechanism. Thermodynamic properties, such as reaction driving force and enthalpy change, were similar to those for a corresponding small molecular analogue, allyl methyl ether (AME), but the addition rate was lower than that for AME. The CC50 values of SAE and HMPP were also obtained by cell experiments. A hemostasis experiment in vivo was performed by comparing the formulation with chitosan and a traditional Chinese medicine (Yunnan Baiyao powder). The result showed that the formulation had a competitive advantage for use in MIS.

SUBMITTER: Zhang Y 

PROVIDER: S-EPMC5681561 | biostudies-literature | 2017 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Minimally Invasive Hemostatic Materials: Tackling a Dilemma of Fluidity and Adhesion by Photopolymerization in situ.

Zhang Yun Y   Song Dandan D   Huang Hong H   Liang Zhiling Z   Liu Houhe H   Huang Yugang Y   Zhong Cheng C   Ye Guodong G  

Scientific reports 20171110 1


Hemostasis in vivo is a key to success in minimally invasive surgery (MIS). However, solid hemostatic materials cannot pass through the sheath tube of the MIS apparatus, while liquid ones are restricted by their low adhesion, which leads to them peeling off of tissue. To tackle the dilemma of fluidity and adhesion, a formulation containing a multifunctional sucrose allyl ether (SAE) monomer and an alpha-hydroxyketone liquid photoinitiator (HMPP) was applied as a lead hemostatic material for MIS.  ...[more]

Similar Datasets

| S-EPMC4755918 | biostudies-literature
| S-EPMC6750270 | biostudies-literature
| S-EPMC5958372 | biostudies-literature
| S-EPMC4734370 | biostudies-literature
| S-EPMC9522468 | biostudies-literature
| S-EPMC6472174 | biostudies-literature
| S-EPMC7556605 | biostudies-literature
| S-EPMC7455468 | biostudies-literature
| S-EPMC6980224 | biostudies-literature