Improved prostate delineation in prostate HDR brachytherapy with TRUS-CT deformable registration technology: A pilot study with MRI validation.


ABSTRACT: Accurate prostate delineation is essential to ensure proper target coverage and normal-tissue sparing in prostate HDR brachytherapy. We have developed a prostate HDR brachytherapy technology that integrates intraoperative TRUS-based prostate contour into HDR treatment planning through TRUS-CT deformable registration (TCDR) to improve prostate contour accuracy. In a perspective study of 16 patients, we investigated the clinical feasibility as well as the performance of this TCDR-based HDR approach. We compared the performance of the TCDR-based approach with the conventional CT-based HDR in terms of prostate contour accuracy using MRI as the gold standard. For all patients, the average Dice prostate volume overlap was 91.1 ± 2.3% between the TCDR-based and the MRI-defined prostate volumes. In a subset of eight patients, inter and intro-observer reliability study was conducted among three experienced physicians (two radiation oncologists and one radiologist) for the TCDR-based HDR approach. Overall, a 10 to 40% improvement in prostate volume accuracy can be achieved with the TCDR-based approach as compared with the conventional CT-based prostate volumes. The TCDR-based prostate volumes match closely to the MRI-defined prostate volumes for all 3 observers (mean volume difference: 0.5 ± 7.2%, 1.8 ± 7.2%, and 3.5 ± 5.1%); while CT-based contours overestimated prostate volumes by 10.9 ± 28.7%, 13.7 ± 20.1%, and 44.7 ± 32.1%. This study has shown that the TCDR-based HDR brachytherapy is clinically feasible and can significantly improve prostate contour accuracy over the conventional CT-based prostate contour. We also demonstrated the reliability of the TCDR-based prostate delineation. This TCDR-based HDR approach has the potential to enable accurate dose planning and delivery, and potentially enhance prostate HDR treatment outcome.

SUBMITTER: Yang X 

PROVIDER: S-EPMC5689894 | biostudies-literature | 2017 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Improved prostate delineation in prostate HDR brachytherapy with TRUS-CT deformable registration technology: A pilot study with MRI validation.

Yang Xiaofeng X   Rossi Peter J PJ   Jani Ashesh B AB   Mao Hui H   Zhou Zhengyang Z   Curran Walter J WJ   Liu Tian T  

Journal of applied clinical medical physics 20170101 1


Accurate prostate delineation is essential to ensure proper target coverage and normal-tissue sparing in prostate HDR brachytherapy. We have developed a prostate HDR brachytherapy technology that integrates intraoperative TRUS-based prostate contour into HDR treatment planning through TRUS-CT deformable registration (TCDR) to improve prostate contour accuracy. In a perspective study of 16 patients, we investigated the clinical feasibility as well as the performance of this TCDR-based HDR approac  ...[more]

Similar Datasets

| S-EPMC5849829 | biostudies-literature
| S-EPMC7771987 | biostudies-literature
| S-EPMC4678702 | biostudies-literature
| S-EPMC8425918 | biostudies-literature
| S-EPMC4105645 | biostudies-literature
| S-EPMC11302745 | biostudies-literature
| S-EPMC7116020 | biostudies-literature
| S-EPMC5097014 | biostudies-literature
| S-EPMC5514316 | biostudies-literature
| S-EPMC9449500 | biostudies-literature