Is there a preferred IMRT technique for left-breast irradiation?


ABSTRACT: Not all clinics have breath-hold radiotherapy available for left-breast irradiation. However intensity-modulated radiotherapy (IMRT) has also been advocated as a means of lowering heart doses. There is currently no large-scale, long-term follow-up data after breast IMRT and, since dose distributions may differ from classic tangent-based radiotherapy, caution is needed to avoid unexpected worsening of the late toxicity profile. We compared four IMRT techniques for free-breathing left-breast irradiation. Consistent with the aforementioned concerns, our goal in planning was to prioritize organ at risk (OAR) sparing in a way that mimicked tangent-based radiotherapy. Ten simultaneous integrated boost treatment plans (PTVelective = 15 × 2.67 Gy; PTVboost = 15 × 3.35 Gy) were created using 1) hybrid-IMRT (H-IMRT), 2) full IMRT (F-IMRT), and 3) volumetric-modulated arc therapy with two partial arcs (2ARC) and 4) six partial arcs (6ARC). Reduction in OAR mean and low dose was prioritized. End-points included OAR sparing (e.g., heart, left anterior descending artery [LAD+3 mm], lungs, and contralateral breast) and PTV coverage/dose homogeneity. Under these conditions we found the following: 1) H-IMRT provided the best mean and low dose OAR sparing, PTVelective coverage (mean V95% = 98%), PTVboost coverage (V95% = 98%), and PTV homogeneity. However, it delivered most intermediate-high dose to the heart, LAD+3 mm and ipsilateral lung; 2) 6ARC had the best intermediate-high dose sparing, followed by F-IMRT, but this was at the expense of more dose in the contralateral lung and breast and worse PTV coverage (PTVelective mean V95% = 96%/97% and PTVboost mean V95% = 91%/96% for 6ARC/F-IMRT). When trying to spare mean and low dose to OARs, the preferred IMRT technique for left-breast irradiation without breath-hold was H-IMRT. This is currently the standard solution in our institution for left-breast radiotherapy under free-breathing and breath-hold conditions.

SUBMITTER: Jeulink M 

PROVIDER: S-EPMC5690145 | biostudies-literature | 2015 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Is there a preferred IMRT technique for left-breast irradiation?

Jeulink Marloes M   Dahele Max M   Meijnen Philip P   Slotman Ben J BJ   Verbakel Wilko F A R WF  

Journal of applied clinical medical physics 20150508 3


Not all clinics have breath-hold radiotherapy available for left-breast irradiation. However intensity-modulated radiotherapy (IMRT) has also been advocated as a means of lowering heart doses. There is currently no large-scale, long-term follow-up data after breast IMRT and, since dose distributions may differ from classic tangent-based radiotherapy, caution is needed to avoid unexpected worsening of the late toxicity profile. We compared four IMRT techniques for free-breathing left-breast irrad  ...[more]

Similar Datasets

| S-EPMC7299258 | biostudies-literature
| S-EPMC4363530 | biostudies-literature
| S-EPMC9576200 | biostudies-literature
| S-EPMC4650319 | biostudies-literature
| S-EPMC3608042 | biostudies-other
| S-EPMC5723509 | biostudies-literature
| S-EPMC8626798 | biostudies-literature
| S-EPMC9974988 | biostudies-literature
| S-EPMC4484297 | biostudies-literature
| S-EPMC10163674 | biostudies-literature