Unknown

Dataset Information

0

Measurement of Gamma-Irradiated Corneal Patch Graft Thickness After Aqueous Drainage Device Surgery.


ABSTRACT:

Importance

Exposure of the tube of an aqueous drainage device (ADD) through the conjunctiva is a serious complication of ADD surgery. Although placement of gamma-irradiated sterile cornea (GISC) as a patch graft over the tube is commonly performed, exposures still occur.

Objectives

To measure GISC patch graft thickness as a function of time after surgery, estimate the rate of graft thinning, and determine risk factors for graft thinning.

Design, setting, and participants

Cross-sectional study of graft thickness using anterior segment optic coherence tomography (AS-OCT) was conducted at the Wilmer Eye Institute at Johns Hopkins Hospital. A total of 107 patients (120 eyes, 120 ADDs) 18 years or older who underwent ADD surgery at Johns Hopkins with GISC patch graft between July 1, 2010, and October 31, 2016, were enrolled.

Intervention

Implantation of ADD with placement of GISC patch graft over the tube.

Main outcomes and measures

Graft thickness vs time after ADD surgery and risk factors for undetectable graft.

Results

Of the 107 patients included in the analysis, the mean (SD) age of the cohort was 64 (16.2) years, 49 (45.8%) were male, and 43 (40.2%) were African American. The mean time of measurement after surgery was 1.7 years (range, 1 day to 6 years). Thinner grafts were observed as the time after surgery lengthened (??regression coefficient, -60 µm per year since surgery; 95% CI, -80 µm to -40 µm). The odds ratio of undetectable grafts per year after ADD surgery was 2.1 (95% CI, 1.5-3.0; P?Conclusions and relevanceGamma-irradiated sterile corneal patch grafts do not always retain their integrity after ADD surgery. Data from this cross-sectional study showed that on average, the longer the time after surgery, the thinner the graft. These findings suggest that placement of a GISC patch graft is no guarantee against tube exposure, and that better strategies are needed for preventing this complication.

SUBMITTER: de Luna RA 

PROVIDER: S-EPMC5710544 | biostudies-literature | 2017 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Measurement of Gamma-Irradiated Corneal Patch Graft Thickness After Aqueous Drainage Device Surgery.

de Luna Regina A RA   Moledina Ameera A   Wang Jiangxia J   Jampel Henry D HD  

JAMA ophthalmology 20170901 9


<h4>Importance</h4>Exposure of the tube of an aqueous drainage device (ADD) through the conjunctiva is a serious complication of ADD surgery. Although placement of gamma-irradiated sterile cornea (GISC) as a patch graft over the tube is commonly performed, exposures still occur.<h4>Objectives</h4>To measure GISC patch graft thickness as a function of time after surgery, estimate the rate of graft thinning, and determine risk factors for graft thinning.<h4>Design, setting, and participants</h4>Cr  ...[more]

Similar Datasets

| S-EPMC8579793 | biostudies-literature
| S-EPMC6104558 | biostudies-literature
| S-EPMC6136793 | biostudies-literature
| S-EPMC6861079 | biostudies-literature
| S-EPMC10605785 | biostudies-literature
| S-EPMC7519199 | biostudies-literature
2022-05-20 | PXD031320 | Pride
| S-EPMC8986976 | biostudies-literature
| S-EPMC3253021 | biostudies-literature
| S-EPMC5529792 | biostudies-other