Unknown

Dataset Information

0

Prolonged circulatory support with an Impella assist device in the management of cardiogenic shock associated with takotsubo syndrome, severe sepsis and acute respiratory distress syndrome.


ABSTRACT: Severe sepsis has been known to trigger for takotsubo syndrome which is associated with profound physical or emotional stress. Severe sepsis is also associated with sepsis-induced cardiomyopathy, a reversible myocardial depression. We report a case in which a patient with takotsubo syndrome, cardiogenic shock, severe sepsis, and adult respiratory distress syndrome was managed with an Impella Cardiac Power circulatory support device for 108 h (4.5 days) because of sustained hemodynamic compromise. To the best of our knowledge, this represents the longest reported use of the Impella Cardiac Power device for the management of cardiogenic shock in a patient with takotsubo syndrome and severe sepsis. This report also highlights the importance of considering a ventricular assist device in the management of takotsubo syndrome cardiogenic shock with severe sepsis which is unresponsive to maximal medical therapy.

SUBMITTER: Foley ED 

PROVIDER: S-EPMC5734429 | biostudies-literature | 2017

REPOSITORIES: biostudies-literature

altmetric image

Publications

Prolonged circulatory support with an Impella assist device in the management of cardiogenic shock associated with takotsubo syndrome, severe sepsis and acute respiratory distress syndrome.

Foley Edward D ED   Diaz Ricardo R   Castresana Manuel R MR  

SAGE open medical case reports 20171214


Severe sepsis has been known to trigger for takotsubo syndrome which is associated with profound physical or emotional stress. Severe sepsis is also associated with sepsis-induced cardiomyopathy, a reversible myocardial depression. We report a case in which a patient with takotsubo syndrome, cardiogenic shock, severe sepsis, and adult respiratory distress syndrome was managed with an Impella Cardiac Power circulatory support device for 108 h (4.5 days) because of sustained hemodynamic compromise  ...[more]

Similar Datasets

| S-EPMC10683305 | biostudies-literature
| S-EPMC8709300 | biostudies-literature
| S-EPMC6176877 | biostudies-other
| S-EPMC8984099 | biostudies-literature
| S-EPMC7763759 | biostudies-literature
| S-EPMC9898582 | biostudies-literature
| S-EPMC11307802 | biostudies-literature
| S-EPMC9101440 | biostudies-literature
| S-EPMC8375056 | biostudies-literature
| S-EPMC8642629 | biostudies-literature