Fractional Flow Reserve/Instantaneous Wave-Free Ratio Discordance in Angiographically Intermediate Coronary Stenoses: An Analysis Using Doppler-Derived Coronary Flow Measurements.


ABSTRACT: OBJECTIVES:The study sought to determine the coronary flow characteristics of angiographically intermediate stenoses classified as discordant by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR). BACKGROUND:Discordance between FFR and iFR occurs in up to 20% of cases. No comparisons have been reported between the coronary flow characteristics of FFR/iFR discordant and angiographically unobstructed vessels. METHODS:Baseline and hyperemic coronary flow velocity and coronary flow reserve (CFR) were compared across 5 vessel groups: FFR+/iFR+ (108 vessels, n = 91), FFR-/iFR+ (28 vessels, n = 24), FFR+/iFR- (22 vessels, n = 22), FFR-/iFR- (208 vessels, n = 154), and an unobstructed vessel group (201 vessels, n = 153), in a post hoc analysis of the largest combined pressure and Doppler flow velocity registry (IDEAL [Iberian-Dutch-English] collaborators study). RESULTS:FFR disagreed with iFR in 14% (50 of 366). Baseline flow velocity was similar across all 5 vessel groups, including the unobstructed vessel group (p = 0.34 for variance). In FFR+/iFR- discordants, hyperemic flow velocity and CFR were similar to both FFR-/iFR- and unobstructed groups; 37.6 (interquartile range [IQR]: 26.1 to 50.4) cm/s vs. 40.0 [IQR: 29.7 to 52.3] cm/s and 42.2 [IQR: 33.8 to 53.2] cm/s and CFR 2.36 [IQR: 1.93 to 2.81] vs. 2.41 [IQR: 1.84 to 2.94] and 2.50 [IQR: 2.11 to 3.17], respectively (p > 0.05 for all). In FFR-/iFR+ discordants, hyperemic flow velocity, and CFR were similar to the FFR+/iFR+ group; 28.2 (IQR: 20.5 to 39.7) cm/s versus 23.5 (IQR: 16.4 to 34.9) cm/s and CFR 1.44 (IQR: 1.29 to 1.85) versus 1.39 (IQR: 1.06 to 1.88), respectively (p > 0.05 for all). CONCLUSIONS:FFR/iFR disagreement was explained by differences in hyperemic coronary flow velocity. Furthermore, coronary stenoses classified as FFR+/iFR- demonstrated similar coronary flow characteristics to angiographically unobstructed vessels.

SUBMITTER: Cook CM 

PROVIDER: S-EPMC5743106 | biostudies-literature | 2017 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Fractional Flow Reserve/Instantaneous Wave-Free Ratio Discordance in Angiographically Intermediate Coronary Stenoses: An Analysis Using Doppler-Derived Coronary Flow Measurements.

Cook Christopher M CM   Jeremias Allen A   Petraco Ricardo R   Sen Sayan S   Nijjer Sukhjinder S   Shun-Shin Matthew J MJ   Ahmad Yousif Y   de Waard Guus G   van de Hoef Tim T   Echavarria-Pinto Mauro M   van Lavieren Martijn M   Al Lamee Rasha R   Kikuta Yuetsu Y   Shiono Yasutsugu Y   Buch Ashesh A   Meuwissen Martijn M   Danad Ibrahim I   Knaapen Paul P   Maehara Akiko A   Koo Bon-Kwon BK   Mintz Gary S GS   Escaned Javier J   Stone Gregg W GW   Francis Darrel P DP   Mayet Jamil J   Piek Jan J JJ   van Royen Niels N   Davies Justin E JE  

JACC. Cardiovascular interventions 20171201 24


<h4>Objectives</h4>The study sought to determine the coronary flow characteristics of angiographically intermediate stenoses classified as discordant by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR).<h4>Background</h4>Discordance between FFR and iFR occurs in up to 20% of cases. No comparisons have been reported between the coronary flow characteristics of FFR/iFR discordant and angiographically unobstructed vessels.<h4>Methods</h4>Baseline and hyperemic coronary flow vel  ...[more]

Similar Datasets

| S-EPMC6761662 | biostudies-literature
| S-EPMC10602988 | biostudies-literature
| S-EPMC5447668 | biostudies-literature
| S-EPMC6739793 | biostudies-literature
| S-EPMC8080642 | biostudies-literature
| S-EPMC6759899 | biostudies-other
| S-EPMC6046658 | biostudies-literature
| S-EPMC11306421 | biostudies-literature
| S-EPMC7410195 | biostudies-literature
| S-EPMC5586447 | biostudies-literature