An Interlaboratory Evaluation of Drift Tube Ion Mobility-Mass Spectrometry Collision Cross Section Measurements.


ABSTRACT: Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values (DTCCSN2) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DTCCSN2 values are evaluated across three additional laboratories on a commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DTCCSN2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.

SUBMITTER: Stow SM 

PROVIDER: S-EPMC5744684 | biostudies-literature | 2017 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

An Interlaboratory Evaluation of Drift Tube Ion Mobility-Mass Spectrometry Collision Cross Section Measurements.

Stow Sarah M SM   Causon Tim J TJ   Zheng Xueyun X   Kurulugama Ruwan T RT   Mairinger Teresa T   May Jody C JC   Rennie Emma E EE   Baker Erin S ES   Smith Richard D RD   McLean John A JA   Hann Stephan S   Fjeldsted John C JC  

Analytical chemistry 20170816 17


Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental param  ...[more]

Similar Datasets

| S-EPMC6520154 | biostudies-literature
| S-EPMC5853271 | biostudies-literature
| S-EPMC8059067 | biostudies-literature
| S-EPMC7289629 | biostudies-literature
| S-EPMC10843661 | biostudies-literature
| S-EPMC8154562 | biostudies-literature
| S-EPMC9285404 | biostudies-literature
| S-EPMC9302900 | biostudies-literature
| S-EPMC3633476 | biostudies-literature
| S-EPMC7263366 | biostudies-literature