Simultaneous determination of four Sudan dyes in rat blood by UFLC-MS/MS and its application to a pharmacokinetic study in rats.


ABSTRACT: A rapid and sensitive method based on ultrafast liquid chromatography-tandem mass spectrometry was developed and validated for simultaneous determination of Sudan I, Sudan II, Sudan III, and Sudan IV levels in rat whole blood. Cleanert C18 mixed-mode polymeric sorbent was used for effective solid-phase extraction cleanup. Separation was carried out on a reversed-phase C18 column (100 mm×2.1 mm, 1.8 ?m) using 0.1% (v/v) formic acid in water/0.1% (v/v) formic acid in acetonitrile as the mobile phase in gradient elution. Quantification was performed by an electrospray ionization source in the positive multiple reaction monitoring mode using D5-Sudan I as the internal standard. Calibration curves showed good linearity between 0.2 and 20.0 ?g/L, with correlation coefficients higher than 0.9990. The average recovery rates were between 93.05% and 114.98%. The intra- and inter-day relative standard deviations were within 6.2%. The lower limit of quantification was 0.2 ?g/L. All the analytes were found to be stable in a series of stability studies. The proposed method was successfully applied to a pharmacokinetic study of four Sudan dyes after oral administration to rats.

SUBMITTER: Zhu H 

PROVIDER: S-EPMC5762213 | biostudies-literature | 2015 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Simultaneous determination of four Sudan dyes in rat blood by UFLC-MS/MS and its application to a pharmacokinetic study in rats.

Zhu Hao H   Chen Yijun Y   Huang Changshun C   Han Yangyang Y   Zhang Yiwei Y   Xie Shucan S   Chen Xiaohong X   Jin Micong M  

Journal of pharmaceutical analysis 20150318 4


A rapid and sensitive method based on ultrafast liquid chromatography-tandem mass spectrometry was developed and validated for simultaneous determination of Sudan I, Sudan II, Sudan III, and Sudan IV levels in rat whole blood. Cleanert C18 mixed-mode polymeric sorbent was used for effective solid-phase extraction cleanup. Separation was carried out on a reversed-phase C<sub>18</sub> column (100 mm×2.1 mm, 1.8 μm) using 0.1% (v/v) formic acid in water/0.1% (v/v) formic acid in acetonitrile as the  ...[more]

Similar Datasets

| S-EPMC7114774 | biostudies-literature
| S-EPMC9531372 | biostudies-literature
| S-EPMC6539458 | biostudies-literature
| S-EPMC6925819 | biostudies-literature
| S-EPMC6272869 | biostudies-other
| S-EPMC6161084 | biostudies-literature
| S-EPMC6643291 | biostudies-literature
| S-EPMC4871186 | biostudies-literature
| S-EPMC6100046 | biostudies-literature
| S-EPMC6332412 | biostudies-literature