Unknown

Dataset Information

0

Layer number identification of CVD-grown multilayer graphene using Si peak analysis.


ABSTRACT: Since the successful exfoliation of graphene, various methodologies have been developed to identify the number of layers of exfoliated graphene. The optical contrast, Raman G-peak intensity, and 2D-peak line-shape are currently widely used as the first level of inspection for graphene samples. Although the combination analysis of G- and 2D-peaks is powerful for exfoliated graphene samples, its use is limited in chemical vapor deposition (CVD)-grown graphene because CVD-grown graphene consists of various domains with randomly rotated crystallographic axes between layers, which makes the G- and 2D-peaks analysis difficult for use in number identification. We report herein that the Raman Si-peak intensity can be a universal measure for the number identification of multilayered graphene. We synthesized a few-layered graphene via the CVD method and performed Raman spectroscopy. Moreover, we measured the Si-peak intensities from various individual graphene domains and correlated them with the corresponding layer numbers. We then compared the normalized Si-peak intensity of the CVD-grown multilayer graphene with the exfoliated multilayer graphene as a reference and successfully identified the layer number of the CVD-grown graphene. We believe that this Si-peak analysis can be further applied to various 2-dimensional (2D) materials prepared by both exfoliation and chemical growth.

SUBMITTER: No YS 

PROVIDER: S-EPMC5766578 | biostudies-literature | 2018 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Layer number identification of CVD-grown multilayer graphene using Si peak analysis.

No You-Shin YS   Choi Hong Kyw HK   Kim Jin-Soo JS   Kim Hakseong H   Yu Young-Jun YJ   Choi Choon-Gi CG   Choi Jin Sik JS  

Scientific reports 20180112 1


Since the successful exfoliation of graphene, various methodologies have been developed to identify the number of layers of exfoliated graphene. The optical contrast, Raman G-peak intensity, and 2D-peak line-shape are currently widely used as the first level of inspection for graphene samples. Although the combination analysis of G- and 2D-peaks is powerful for exfoliated graphene samples, its use is limited in chemical vapor deposition (CVD)-grown graphene because CVD-grown graphene consists of  ...[more]

Similar Datasets

| S-EPMC4669485 | biostudies-literature
| S-EPMC6115377 | biostudies-literature
| S-EPMC4609947 | biostudies-other
| S-EPMC4725868 | biostudies-other
| S-EPMC4761869 | biostudies-other
| S-EPMC6410133 | biostudies-literature
| S-EPMC8002582 | biostudies-literature
| S-EPMC8433733 | biostudies-literature
| S-EPMC5134252 | biostudies-literature
| S-EPMC6812130 | biostudies-literature