Comparison of rapid MMP-8 and interleukin-6 point-of-care tests to identify intra-amniotic inflammation/infection and impending preterm delivery in patients with preterm labor and intact membranes.


ABSTRACT: OBJECTIVE:Among patients presenting with preterm labor and intact membranes, those with intra-amniotic inflammation have adverse obstetrical and neonatal outcomes. The diagnosis of intra-amniotic inflammation can easily be made by detecting an elevated concentration of the cytokine interleukin (IL)-6 or the enzyme neutrophil collagenase, also known as matrix metalloproteinase (MMP)-8. The diagnostic performances of MMP-8 and IL-6 enzyme-linked immunosorbent assay tests are similar. Recently, a rapid test has become available for point-of-care determination of either MMP-8 or IL-6. The objectives of this study were to compare the diagnostic indices and predictive values between the rapid MMP-8 and IL-6 tests for the identification of intra-amniotic inflammation in patients with preterm labor and intact membranes. MATERIALS AND METHODS:We performed a retrospective cohort study including 124 women with singleton pregnancies who presented with symptoms of preterm labor and underwent transabdominal amniocentesis for the evaluation of microbial invasion of the amniotic cavity (MIAC). MIAC was defined according to amniotic fluid culture results (aerobic and anaerobic bacteria as well as genital Mycoplasmas). Amniotic fluid white blood cell (WBC) counts were determined using a hemocytometer chamber. An elevated amniotic fluid MMP-8 concentration was assessed using Yoon's MMP-8 Check® (cutoff: 10?ng/mL). An elevated amniotic fluid IL-6 concentration was scored when there was a positive result for the lateral flow-based immunoassay (cutoff: ?745?pg/mL and ?1000?pg/mL). In order to objectively compare rapid MMP-8 and rapid IL-6 tests to identify intra-amniotic inflammation, an amniotic fluid WBC count of ?50 cells/mm3 was used to define intra-amniotic inflammation. RESULTS:(1) The rapid tests had the same sensitivity for the detection of intra-amniotic inflammation [85.7% (18/21) for all]; (2) the specificity of the rapid MMP-8 test was higher than that of the rapid IL-6 test (cutoff: 745?pg/mL) for the identification of intra-amniotic inflammation [72.8% (75/103) vs. 64.1% (66/103); p?

SUBMITTER: Chaemsaithong P 

PROVIDER: S-EPMC5769687 | biostudies-literature | 2018 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of rapid MMP-8 and interleukin-6 point-of-care tests to identify intra-amniotic inflammation/infection and impending preterm delivery in patients with preterm labor and intact membranes.

Chaemsaithong Piya P   Chaemsaithong Piya P   Romero Roberto R   Docheva Nikolina N   Chaiyasit Noppadol N   Bhatti Gaurav G   Pacora Percy P   Hassan Sonia S SS   Yeo Lami L   Erez Offer O  

The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians 20170301 2


<h4>Objective</h4>Among patients presenting with preterm labor and intact membranes, those with intra-amniotic inflammation have adverse obstetrical and neonatal outcomes. The diagnosis of intra-amniotic inflammation can easily be made by detecting an elevated concentration of the cytokine interleukin (IL)-6 or the enzyme neutrophil collagenase, also known as matrix metalloproteinase (MMP)-8. The diagnostic performances of MMP-8 and IL-6 enzyme-linked immunosorbent assay tests are similar. Recen  ...[more]

Similar Datasets

| S-EPMC8224929 | biostudies-literature
| S-EPMC5991674 | biostudies-literature
| S-EPMC6788958 | biostudies-literature
| S-EPMC8314747 | biostudies-literature
| S-EPMC6908687 | biostudies-literature
2024-03-13 | GSE243831 | GEO
2021-02-01 | GSE155526 | GEO
| S-EPMC8091089 | biostudies-literature
| S-EPMC3800180 | biostudies-literature
| S-EPMC6497524 | biostudies-literature