Unknown

Dataset Information

0

Photocleavage-based affinity purification of biomarkers from serum: Application to multiplex allergy testing.


ABSTRACT: Multiplex serological immunoassays, such as implemented on microarray or microsphere-based platforms, provide greater information content and higher throughput, while lowering the cost and blood volume required. These features are particularly attractive in pediatric food allergy testing to facilitate high throughput multi-allergen analysis from finger- or heel-stick collected blood. However, the miniaturization and microfluidics necessary for creating multiplex assays make them highly susceptible to the "matrix effect" caused by interference from non-target agents in serum and other biofluids. Such interference can result in lower sensitivity, specificity, reproducibility and quantitative accuracy. These problems have in large part prevented wide-spread implementation of multiplex immunoassays in clinical laboratories. We report the development of a novel method to eliminate the matrix effect by utilizing photocleavable capture antibodies to purify and concentrate blood-based biomarkers (a process termed PC-PURE) prior to detection in a multiplex immunoassay. To evaluate this approach, it was applied to blood-based allergy testing. Patient total IgE was purified and enriched using PC-PURE followed by multiplex microsphere-based detection of allergen-specific IgEs (termed the AllerBead assay). AllerBead was formatted to detect the eight most common pediatric food allergens: milk, soy, wheat, egg, peanuts, tree nuts, fin fish and shellfish, which account for >90% of all pediatric food allergies. 205 serum samples obtained from Boston Children's Hospital were evaluated. When PC-PURE was employed with AllerBead, excellent agreement was obtained with the standard, non-multiplex, ImmunoCAP® assay (average sensitivity above published negative predictive cutoffs = 96% and average Pearson r = 0.90; average specificity = 97%). In contrast, poor ImmunoCAP®-correlation was observed when PC-PURE was not utilized (average sensitivity above published negative predictive cutoffs = 59% and average Pearson r = 0.61; average specificity = 97%). This approach should be adaptable to improve a wide range of multiplex immunoassays such as in cancer, infectious disease and autoimmune disease.

SUBMITTER: Wan Z 

PROVIDER: S-EPMC5794080 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

Photocleavage-based affinity purification of biomarkers from serum: Application to multiplex allergy testing.

Wan Zhi Z   Ostendorff Heather P HP   Liu Ziying Z   Schneider Lynda C LC   Rothschild Kenneth J KJ   Lim Mark J MJ  

PloS one 20180201 2


Multiplex serological immunoassays, such as implemented on microarray or microsphere-based platforms, provide greater information content and higher throughput, while lowering the cost and blood volume required. These features are particularly attractive in pediatric food allergy testing to facilitate high throughput multi-allergen analysis from finger- or heel-stick collected blood. However, the miniaturization and microfluidics necessary for creating multiplex assays make them highly susceptib  ...[more]

Similar Datasets

| S-EPMC2784287 | biostudies-literature
| S-EPMC10093013 | biostudies-literature
| S-EPMC4332410 | biostudies-literature
2022-04-30 | GSE199016 | GEO
| S-EPMC5676709 | biostudies-literature
| S-EPMC8698985 | biostudies-literature
| S-EPMC6399902 | biostudies-literature
| S-EPMC5931628 | biostudies-literature
| S-EPMC9899493 | biostudies-literature