Exploring an optimal wavelet-based filter for cryo-ET imaging.


ABSTRACT: Cryo-electron tomography (cryo-ET) is one of the most advanced technologies for the in situ visualization of molecular machines by producing three-dimensional (3D) biological structures. However, cryo-ET imaging has two serious disadvantages-low dose and low image contrast-which result in high-resolution information being obscured by noise and image quality being degraded, and this causes errors in biological interpretation. The purpose of this research is to explore an optimal wavelet denoising technique to reduce noise in cryo-ET images. We perform tests using simulation data and design a filter using the optimum selected wavelet parameters (three-level decomposition, level-1 zeroed out, subband-dependent threshold, a soft-thresholding and spline-based discrete dyadic wavelet transform (DDWT)), which we call a modified wavelet shrinkage filter; this filter is suitable for noisy cryo-ET data. When testing using real cryo-ET experiment data, higher quality images and more accurate measures of a biological structure can be obtained with the modified wavelet shrinkage filter processing compared with conventional processing. Because the proposed method provides an inherent advantage when dealing with cryo-ET images, it can therefore extend the current state-of-the-art technology in assisting all aspects of cryo-ET studies: visualization, reconstruction, structural analysis, and interpretation.

SUBMITTER: Huang X 

PROVIDER: S-EPMC5803242 | biostudies-literature | 2018 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Exploring an optimal wavelet-based filter for cryo-ET imaging.

Huang Xinrui X   Li Sha S   Gao Song S  

Scientific reports 20180207 1


Cryo-electron tomography (cryo-ET) is one of the most advanced technologies for the in situ visualization of molecular machines by producing three-dimensional (3D) biological structures. However, cryo-ET imaging has two serious disadvantages-low dose and low image contrast-which result in high-resolution information being obscured by noise and image quality being degraded, and this causes errors in biological interpretation. The purpose of this research is to explore an optimal wavelet denoising  ...[more]

Similar Datasets

| S-EPMC6960407 | biostudies-literature
| S-EPMC8832990 | biostudies-literature
| S-EPMC6072063 | biostudies-literature
| S-EPMC4416937 | biostudies-literature
| S-EPMC10218330 | biostudies-literature
| S-EPMC5928853 | biostudies-literature
| S-EPMC3607703 | biostudies-literature
| S-EPMC10955043 | biostudies-literature
| S-EPMC10791666 | biostudies-literature
| S-EPMC9388967 | biostudies-literature