Unknown

Dataset Information

0

Murine pulmonary imaging at 7T: T2* and T1 with anisotropic UTE.


ABSTRACT: PURPOSE:To measure the T2* and T1 of mouse lung at 7T via anisotropic-resolution radial ultrashort echo-time imaging with ellipsoidal k-space coverage. METHODS:Ellipsoidal field-of-view was created by expanding uniform spherical k-space coverage. The effects of T2* and ellipsoidal sampling on image resolution were investigated by using point-spread-function analysis and resolution phantoms. Finally, this ellipsoidal sampling approach was used to measure the lung T2* and T1 of healthy C57BL/6 mice at the increasingly common preclinical field strength of 7T. RESULTS:Lung parenchyma T2* of 17- to 23-week-old mice at 7T was 0.395?±?0.033 ms. T1 of lung and left- and right-heart ventricles was 1452.5?±?87.0 ms, 1810.5?±?54.6 ms, and 1602.6?±?120.9 ms, respectively. Ellipsoidal k-space sampling provides enhanced resolution for a fixed scanning time or provides equivalent (although anisotropic) spatial resolution with reduced scanning times, while simultaneously avoiding fold-in artifacts. CONCLUSION:Using these techniques, the first T2* and T1 measures of mouse lung at 7T are reported. Ultrashort echo-time imaging with ellipsoidal k-space coverage significantly increases in-plane resolution without increasing scanning time, or equivalently, decreases scanning time while maintaining equivalent in-plane resolution. Magn Reson Med 79:2254-2264, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

SUBMITTER: Guo J 

PROVIDER: S-EPMC5811363 | biostudies-literature | 2018 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Murine pulmonary imaging at 7T: T2* and T<sub>1</sub> with anisotropic UTE.

Guo Jinbang J   Cao Xuefeng X   Cleveland Zackary I ZI   Woods Jason C JC  

Magnetic resonance in medicine 20170815 4


<h4>Purpose</h4>To measure the T2* and T<sub>1</sub> of mouse lung at 7T via anisotropic-resolution radial ultrashort echo-time imaging with ellipsoidal k-space coverage.<h4>Methods</h4>Ellipsoidal field-of-view was created by expanding uniform spherical k-space coverage. The effects of T2* and ellipsoidal sampling on image resolution were investigated by using point-spread-function analysis and resolution phantoms. Finally, this ellipsoidal sampling approach was used to measure the lung T2* and  ...[more]

Similar Datasets

| S-EPMC5912804 | biostudies-literature
| S-EPMC4334264 | biostudies-literature
| S-EPMC3638061 | biostudies-literature
| S-EPMC7677167 | biostudies-literature
| S-EPMC6252279 | biostudies-literature
| S-EPMC5278879 | biostudies-literature
| S-EPMC7083696 | biostudies-literature
| S-EPMC8252099 | biostudies-literature
| S-EPMC5821562 | biostudies-literature
| S-EPMC6581466 | biostudies-literature