Unknown

Dataset Information

0

Accuracy and precision of consumer-level activity monitors for stroke detection during wheelchair propulsion and arm ergometry.


ABSTRACT: The purpose of this study was to evaluate whether consumer-level activity trackers can estimate wheelchair strokes and arm ergometer revolutions. Thirty able-bodied participants wore three consumer-level activity trackers (Garmin VivoFit, FitBit Flex, and Jawbone UP24) on the wrist. Participants propelled a wheelchair at fixed frequencies (30, 45 and 60 strokes per minute (spm)) three minutes each and at pre-determined varied frequencies, (30-80 spm) for two minutes. Participants also freely wheeled through an obstacle course. 10 other participants performed arm-ergometry at 40, 60 and 80 revolutions per minute (rpm), for three minutes each. Mean percentage error (MPE(SD)) for 30 spm were ?46(26)% for all monitors, and declined to 3-6(2-7)% at 60 spm. For the obstacle course, MPE ranged from 12-17(7-13)% for all trackers. For arm-ergometry, MPE was at 1-96(0-37)% with the best measurement for the Fitbit at 60 and 80 rpm, and the Garmin at 80rpm, with MPE = 1(0-1)%. The consumer-level wrist-worn activity trackers we tested have higher accuracy/precision at higher movement frequencies but perform poorly at lower frequencies.

SUBMITTER: Kressler J 

PROVIDER: S-EPMC5812573 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accuracy and precision of consumer-level activity monitors for stroke detection during wheelchair propulsion and arm ergometry.

Kressler Jochen J   Koeplin-Day Joshua J   Muendle Benedikt B   Rosby Brice B   Santo Elizabeth E   Domingo Antoinette A  

PloS one 20180214 2


The purpose of this study was to evaluate whether consumer-level activity trackers can estimate wheelchair strokes and arm ergometer revolutions. Thirty able-bodied participants wore three consumer-level activity trackers (Garmin VivoFit, FitBit Flex, and Jawbone UP24) on the wrist. Participants propelled a wheelchair at fixed frequencies (30, 45 and 60 strokes per minute (spm)) three minutes each and at pre-determined varied frequencies, (30-80 spm) for two minutes. Participants also freely whe  ...[more]

Similar Datasets

| S-EPMC5894999 | biostudies-literature
| S-EPMC4842047 | biostudies-literature
| S-EPMC9354471 | biostudies-literature
| S-EPMC9301377 | biostudies-literature
| S-EPMC9397688 | biostudies-literature
| S-EPMC4884508 | biostudies-literature
| S-EPMC7302523 | biostudies-literature
| S-EPMC6743766 | biostudies-literature
| S-EPMC4655152 | biostudies-literature
| S-EPMC4515595 | biostudies-literature