Unknown

Dataset Information

0

Test-Retest Reliability and Agreement Between In-Person and Video Assessment of Facial Mimetic Function Using the eFACE Facial Grading System.


ABSTRACT: Use of a robust high-resolution instrument for grading of facial symmetry would enhance reporting the outcomes of facial reanimation interventions. The eFACE is one such tool.To determine test-retest reliability of the eFACE tool over time and agreement between eFACE assessments made in person vs those made using video of facial mimetic function.A prospective observational study was conducted among 75 consecutive patients with varying degrees of facial palsy who presented between July 1 and December 31, 2014, to an academic tertiary referral hospital. Facial symmetry of all patients was graded in person and via standardized photographic and video documentation of facial mimetic function at the initial visit. Three months after initial presentation, eFACE scores were reassessed by the same raters using the videos of facial mimetic function documented at the initial visit.Individual and subset eFACE scores assessed by 2 facial reanimation surgeons.Among the 75 patients in the study (mean [SD] age, 48.18 [16.60] years; 30 men and 45 women), agreement between in-person and video assessments of facial function using the eFACE scale was excellent (static subset score: mean difference, 0.19; 95% CI, -1.51 to 1.88; P?=?.83; intraclass correlation coefficient [ICC], 0.85; 95% CI, 0.80 to 0.89; dynamic subset score: mean difference, -0.51; 95% CI, -1.72 to 0.71; P?=?.41; ICC, 0.96; 95% CI, 0.94 to 0.97; synkinesis subset score: mean difference, -1.14; 95% CI, -2.87 to 0.59; P?=?.20; ICC, 0.90; 95% CI, 0.86 to 0.93; and composite score: mean difference, -0.41; 95% CI, -1.30 to 0.47; P?=?.36; ICC, 0.94; 95% CI, 0.92 to 0.96). Agreement between repeated eFACE assessments of video of facial function was excellent (static subset score: ICC, 0.93; 95% CI, 0.87 to 0.96; dynamic subset score: ICC, 0.88; 95% CI, 0.80 to 0.94; synkinesis subset score: ICC, 0.92; 95% CI, 0.86 to 0.96; and composite score: ICC, 0.96; 95% CI, 0.93 to 0.98).Strong agreement exists between eFACE scores of facial function assessed in person and from video recordings. Test-retest reliability of eFACE scores is high. The eFACE is a reliable instrument for high-resolution assessment of facial mimetic function.NA.

SUBMITTER: Banks CA 

PROVIDER: S-EPMC5815128 | biostudies-literature | 2017 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Test-Retest Reliability and Agreement Between In-Person and Video Assessment of Facial Mimetic Function Using the eFACE Facial Grading System.

Banks Caroline A CA   Jowett Nate N   Hadlock Tessa A TA  

JAMA facial plastic surgery 20170501 3


<h4>Importance</h4>Use of a robust high-resolution instrument for grading of facial symmetry would enhance reporting the outcomes of facial reanimation interventions. The eFACE is one such tool.<h4>Objective</h4>To determine test-retest reliability of the eFACE tool over time and agreement between eFACE assessments made in person vs those made using video of facial mimetic function.<h4>Design, setting, and participants</h4>A prospective observational study was conducted among 75 consecutive pati  ...[more]

Similar Datasets

| S-EPMC5568997 | biostudies-literature
| S-EPMC4788471 | biostudies-other
| S-EPMC6950610 | biostudies-literature
| S-EPMC6118382 | biostudies-literature
| S-EPMC4547115 | biostudies-literature
| S-EPMC3827856 | biostudies-literature
| S-EPMC4411010 | biostudies-literature
| S-EPMC5686420 | biostudies-literature