Variation in Positive End-Expiratory Pressure Levels for Mechanically Ventilated Extremely Low Birth Weight Infants.


ABSTRACT: OBJECTIVE:To test the hypothesis that significant positive end-expiratory pressure (PEEP) level variation exists between neonatal centers. STUDY DESIGN:We performed a secondary analysis cohort study of the Nasal Intermittent Positive-Pressure Ventilation trial. Our study population was extremely low birth weight infants requiring mechanical ventilation within 28 days of life. The exposure was neonatal center; 34 international centers participated in the trial. Subjects from centers with fewer than 5 eligible cases were excluded. The main outcome was the maximal PEEP level used during the first course of mechanical ventilation. Infant characteristics judged a priori to directly influence clinical PEEP level selection and all characteristics associated with PEEP at P <.05 in bivariable analyses were included with and without center in multivariable linear regression models. Variation in PEEP level use between centers following adjustment for infant characteristics was assessed. RESULTS:A total of 278 extremely low birth weight infants from 17 centers were included. Maximal PEEP ranged from 3 to 9 cm H2O, mean = 5.7 (SD = 0.9). Significant variation between centers remained despite adjustment for infant characteristics (P < .0001). Further, center alone explained a greater proportion of the PEEP level variation than all infant characteristics combined. CONCLUSIONS:Marked variation in PEEP levels for extremely low birth weight infants exists between neonatal centers. Research providing evidence-based guidance for this important aspect of respiratory care in preterm infants at high risk of lung injury is needed. TRIAL REGISTRATION:ClinicalTrials.gov: NCT00433212.

SUBMITTER: Bamat NA 

PROVIDER: S-EPMC5826866 | biostudies-literature | 2018 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Variation in Positive End-Expiratory Pressure Levels for Mechanically Ventilated Extremely Low Birth Weight Infants.

Bamat Nicolas A NA   Guevara James P JP   Bryan Matthew M   Roberts Robin S RS   Yoder Bradley A BA   Lemyre Brigitte B   Chiu Aaron A   Millar David D   Kirpalani Haresh H  

The Journal of pediatrics 20171222


<h4>Objective</h4>To test the hypothesis that significant positive end-expiratory pressure (PEEP) level variation exists between neonatal centers.<h4>Study design</h4>We performed a secondary analysis cohort study of the Nasal Intermittent Positive-Pressure Ventilation trial. Our study population was extremely low birth weight infants requiring mechanical ventilation within 28 days of life. The exposure was neonatal center; 34 international centers participated in the trial. Subjects from center  ...[more]

Similar Datasets

| S-EPMC8520168 | biostudies-literature
| S-EPMC8558243 | biostudies-literature
| S-EPMC7900494 | biostudies-literature
| S-EPMC8796179 | biostudies-literature
| S-EPMC11427533 | biostudies-literature
| S-EPMC6201576 | biostudies-literature
| S-EPMC10962429 | biostudies-literature
| S-EPMC10645805 | biostudies-literature
| S-EPMC4574463 | biostudies-literature
| S-EPMC8478787 | biostudies-literature