Unknown

Dataset Information

0

Safety and Immunogenicity of PENNVAX-G DNA Prime Administered by Biojector 2000 or CELLECTRA Electroporation Device With Modified Vaccinia Ankara-CMDR Boost.


ABSTRACT: Background:We report the first-in-human safety and immunogenicity evaluation of PENNVAX-G DNA/modified vaccinia Ankara-Chiang Mai double recombinant (MVA-CMDR) prime-boost human immuonodeficiency virus (HIV) vaccine, with intramuscular DNA delivery by either Biojector 2000 needle-free injection system (Biojector) or CELLECTRA electroporation device. Methods:Healthy, HIV-uninfected adults were randomized to receive 4 mg of PENNVAX-G DNA delivered intramuscularly by Biojector or electroporation at baseline and week 4 followed by intramuscular injection of 108 plaque forming units of MVA-CMDR at weeks 12 and 24. The open-label part A was conducted in the United States, followed by a double-blind, placebo-controlled part B in East Africa. Solicited and unsolicited adverse events were recorded, and immune responses were measured. Results:Eighty-eight of 100 enrolled participants completed all study injections, which were generally safe and well tolerated, with more immediate, but transient, pain in the electroporation group. Cellular responses were observed in 57% of vaccine recipients tested and were CD4 predominant. High rates of binding antibody responses to CRF01_AE antigens, including gp70 V1V2 scaffold, were observed. Neutralizing antibodies were detected in a peripheral blood mononuclear cell assay, and moderate antibody-dependent, cell-mediated cytotoxicity activity was demonstrated. Discussion:The PVG/MVA-CMDR HIV-1 vaccine regimen is safe and immunogenic. Substantial differences in safety or immunogenicity between modes of DNA delivery were not observed. Clinical Trials Registration:NCT01260727.

SUBMITTER: Ake JA 

PROVIDER: S-EPMC5853809 | biostudies-literature | 2017 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Safety and Immunogenicity of PENNVAX-G DNA Prime Administered by Biojector 2000 or CELLECTRA Electroporation Device With Modified Vaccinia Ankara-CMDR Boost.

Ake Julie A JA   Schuetz Alexandra A   Pegu Poonam P   Wieczorek Lindsay L   Eller Michael A MA   Kibuuka Hannah H   Sawe Fredrick F   Maboko Leonard L   Polonis Victoria V   Karasavva Nicos N   Weiner David D   Sekiziyivu Arthur A   Kosgei Josphat J   Missanga Marco M   Kroidl Arne A   Mann Philipp P   Ratto-Kim Silvia S   Anne Eller Leigh L   Earl Patricia P   Moss Bernard B   Dorsey-Spitz Julie J   Milazzo Mark M   Laissa Ouedraogo G G   Rizvi Farrukh F   Yan Jian J   Khan Amir S AS   Peel Sheila S   Sardesai Niranjan Y NY   Michael Nelson L NL   Ngauy Viseth V   Marovich Mary M   Robb Merlin L ML  

The Journal of infectious diseases 20171101 9


<h4>Background</h4>We report the first-in-human safety and immunogenicity evaluation of PENNVAX-G DNA/modified vaccinia Ankara-Chiang Mai double recombinant (MVA-CMDR) prime-boost human immuonodeficiency virus (HIV) vaccine, with intramuscular DNA delivery by either Biojector 2000 needle-free injection system (Biojector) or CELLECTRA electroporation device.<h4>Methods</h4>Healthy, HIV-uninfected adults were randomized to receive 4 mg of PENNVAX-G DNA delivered intramuscularly by Biojector or ele  ...[more]

Similar Datasets

| S-EPMC3592345 | biostudies-literature
| S-EPMC5571275 | biostudies-literature
| S-EPMC4687051 | biostudies-literature
| S-EPMC6600201 | biostudies-literature
| S-EPMC1892755 | biostudies-literature
| S-EPMC7455681 | biostudies-literature
| S-EPMC5564012 | biostudies-literature
| S-EPMC6450106 | biostudies-literature
| S-EPMC3016847 | biostudies-literature
| S-EPMC5558987 | biostudies-other