Pacemaker Implantation Associated Myocardial Micro-Damage: A Randomised Comparison between Active and Passive Fixation Leads.


ABSTRACT: Fixation of the pacemaker leads during pacemaker implantation leads to an increase of cardiac Troponin T (cTnT) that can be interpreted as a sign of minimal myocardial damage. This trial evaluates whether the mechanism type of lead fixation influences the magnitude of cTnT release. Patients having a de-novo cardiac pacemaker implantation or a lead revision were centrally randomized to receive either a ventricular lead with an active (screw) or passive (tine) fixation mechanism. High-sensitive Troponin T (hsTnT) was determined on the day of the procedure beforehand and on the following day. 326 Patients (median age (IQR) 75.0 (69.0-80.0) years, 64% male) from six international centers were randomized to receive ventricular leads with an active (n?=?166) or passive (n?=?160) fixation mechanism. Median (IQR) hsTnT levels increased by 0.009 (0.004-0.021) ng/ml in the group receiving screw-in ventricular leads and by 0.008 (0.003-0.030) ng/ml in the group receiving tined ventricular leads (n.s.). In conclusion pacemaker implantations are followed by a release of hsTnT. The choice between active or passive fixation ventricular leads does not have a significant influence on the extent of myocardial injury and the magnitude of hsTnT release.

SUBMITTER: Blazek P 

PROVIDER: S-EPMC5861101 | biostudies-literature | 2018 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Pacemaker Implantation Associated Myocardial Micro-Damage: A Randomised Comparison between Active and Passive Fixation Leads.

Blažek Patrick P   Ferri-Certić Jerko J   Vražić Hrvoje H   Lennerz Carsten C   Grebmer Christian C   Kaitani Kazuaki K   Karch Martin M   Starčević Boris B   Semmler Verena V   Kolb Christof C  

Scientific reports 20180320 1


Fixation of the pacemaker leads during pacemaker implantation leads to an increase of cardiac Troponin T (cTnT) that can be interpreted as a sign of minimal myocardial damage. This trial evaluates whether the mechanism type of lead fixation influences the magnitude of cTnT release. Patients having a de-novo cardiac pacemaker implantation or a lead revision were centrally randomized to receive either a ventricular lead with an active (screw) or passive (tine) fixation mechanism. High-sensitive Tr  ...[more]

Similar Datasets

| S-EPMC4847909 | biostudies-literature
| S-EPMC5870196 | biostudies-other
| S-EPMC8556553 | biostudies-literature
| S-EPMC10808522 | biostudies-literature
| S-EPMC5336930 | biostudies-literature
| S-EPMC6125407 | biostudies-literature
| S-EPMC6288034 | biostudies-literature
| S-EPMC5808486 | biostudies-literature
| S-EPMC6602091 | biostudies-literature
| S-EPMC7718507 | biostudies-literature