Predictors of Hemodynamic Improvement and Stabilization Following Intraaortic Balloon Pump Implantation in Patients With Advanced Heart Failure.


ABSTRACT: The intraaortic balloon pump (IABP) is currently an essential tool to improve hemodynamics in patients with advanced heart failure (HF). This study investigated predictors for hemodynamic improvement or stabilization with IABP therapy in patients with advanced HF.Patients with advanced HF and hemodynamic deterioration treated with IABP were enrolled in this retrospective study. Invasive hemodynamics were measured before IABP implantation and 2 weeks after IABP initiation. Significant degree of hemodynamic improvement was defined as 30% improvement in all three of the following variables: central venous pressure (CVP); pulmonary capillary wedge pressure (PCWP); and cardiac index (CI). Hemodynamic stabilization was counted in patients reaching CVP <12 mm Hg, PCWP <18 mm Hg, and CI >2.0 L/min/m² or CI >2.2 L/min/m² on inotropes.Ninety-one patients (55 ± 12 years; 78% males) were evaluated. Seventeen patients (18.7%) achieved significant hemodynamic improvement, and baseline CVP >16 mm Hg was associated with this endpoint (P<.05). Thirty-two patients (35.2%) achieved hemodynamic stabilization; lower baseline heart rate (HR) and PCWP were associated with this stabilization (P<.05). Patients with HR <92 beats/min and PCWP <25 mm Hg achieved hemodynamic stabilization more frequently than those without HR <92 beats/min and PCWP <25 mm Hg (66.7% vs 19.7%; P<.05).Elevated CVP and lower HR and PCWP before IABP initiation help predict high response to IABP.

SUBMITTER: Imamura T 

PROVIDER: S-EPMC5862635 | biostudies-literature | 2018 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Predictors of Hemodynamic Improvement and Stabilization Following Intraaortic Balloon Pump Implantation in Patients With Advanced Heart Failure.

Imamura Teruhiko T   Juricek Colleen C   Nguyen Ann A   Chung Ben B   Rodgers Daniel D   Sayer Gabriel G   Sarswat Nitasha N   Kim Gene G   Raikhelkar Jayant J   Ota Takeyoshi T   Song Tae T   Onsanger David D   Burkhoff Daniel D   Jeevanandam Valluvan V   Uriel Nir N  

The Journal of invasive cardiology 20180115 2


<h4>Objectives</h4>The intraaortic balloon pump (IABP) is currently an essential tool to improve hemodynamics in patients with advanced heart failure (HF). This study investigated predictors for hemodynamic improvement or stabilization with IABP therapy in patients with advanced HF.<h4>Methods</h4>Patients with advanced HF and hemodynamic deterioration treated with IABP were enrolled in this retrospective study. Invasive hemodynamics were measured before IABP implantation and 2 weeks after IABP  ...[more]

Similar Datasets

| S-EPMC5955398 | biostudies-literature
| S-EPMC7687352 | biostudies-literature
| S-EPMC6148415 | biostudies-literature
| S-EPMC6586004 | biostudies-literature
| S-EPMC4630130 | biostudies-literature
| S-EPMC8079106 | biostudies-literature
| S-EPMC4779722 | biostudies-literature
| S-EPMC7374011 | biostudies-literature
| S-EPMC4305252 | biostudies-literature
| S-EPMC4295071 | biostudies-literature