Ontology highlight
ABSTRACT: Background
The purpose of this study was to evaluate the efficacy of a quantitative analysis method for comitant exotropia using video-oculography (VOG) with alternate cover.Methods
Thirty-four subjects with comitant exotropia were included. Two independent ophthalmologists measured the angle of ocular deviation using the alternate prism cover test (APCT). The video files and data of changes in ocular deviation during the alternate cover test were obtained using VOG. To verify the accuracy of VOG, the value obtained using VOG and the angle of a rotating model eye were compared, and a new linear equation was subsequently derived using these data. The calculated values obtained using VOG were compared with those obtained using the APCT.Results
Rotation of the model eye and the values obtained using VOG demonstrated excellent positive correlation (R = 1.000; p < 0.001). A simple linear regression model was obtained: rotation of the model eye = 0.978 × value obtained using VOG for a model eye - 0.549. The 95% limit of agreement for inter-observer variability was ±4.63 prism diopters (PD) for APCT and that for test-retest variability was ±3.56 PD for the VOG test. The results of APCT and calculated VOG test demonstrated a strong positive correlation. Bland-Altman plots revealed no overall tendency for the calculated values obtained from VOG to differ from those obtained using APCT.Conclusions
VOG with alternate cover is a non-invasive and accurate tool for quantitatively measuring and recording ocular deviation. In particular, it is independent of the proficiency of the examiner and, can therefore, be useful in the absence of skilled personnel.Trial registration
ClinicalTrial.gov, NCT03119311 , Date of registration: 04/17/2017, Date of enrolment of the first participant to the trial: 04/25/2017.
SUBMITTER: Park N
PROVIDER: S-EPMC5863817 | biostudies-literature | 2018 Mar
REPOSITORIES: biostudies-literature
Park Nohae N Park Byunggun B Oh Minkyung M Moon Sunghyuk S Kim Myungmi M
BMC ophthalmology 20180322 1
<h4>Background</h4>The purpose of this study was to evaluate the efficacy of a quantitative analysis method for comitant exotropia using video-oculography (VOG) with alternate cover.<h4>Methods</h4>Thirty-four subjects with comitant exotropia were included. Two independent ophthalmologists measured the angle of ocular deviation using the alternate prism cover test (APCT). The video files and data of changes in ocular deviation during the alternate cover test were obtained using VOG. To verify th ...[more]