Unknown

Dataset Information

0

Quantitative real-time optical imaging of the tissue metabolic rate of oxygen consumption.


ABSTRACT: The tissue metabolic rate of oxygen consumption (tMRO2) is a clinically relevant marker for a number of pathologies including cancer and arterial occlusive disease. We present and validate a noncontact method for quantitatively mapping tMRO2 over a wide, scalable field of view at 16??frames??/??s. We achieve this by developing a dual-wavelength, near-infrared coherent spatial frequency-domain imaging (cSFDI) system to calculate tissue optical properties (i.e., absorption, ?a, and reduced scattering, ?s', parameters) as well as the speckle flow index (SFI) at every pixel. Images of tissue oxy- and deoxyhemoglobin concentration (??[??HbO2??]?? and [HHb]) are calculated from optical properties and combined with SFI to calculate tMRO2. We validate the system using a series of yeast-hemoglobin tissue-simulating phantoms and conduct in vivo tests in humans using arterial occlusions that demonstrate sensitivity to tissue metabolic oxygen debt and its repayment. Finally, we image the impact of cyanide exposure and toxicity reversal in an in vivo rabbit model showing clear instances of mitochondrial uncoupling and significantly diminished tMRO2. We conclude that dual-wavelength cSFDI provides rapid, quantitative, wide-field mapping of tMRO2 that can reveal unique spatial and temporal dynamics relevant to tissue pathology and viability.

SUBMITTER: Ghijsen M 

PROVIDER: S-EPMC5866507 | biostudies-literature | 2018 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantitative real-time optical imaging of the tissue metabolic rate of oxygen consumption.

Ghijsen Michael M   Lentsch Griffin R GR   Gioux Sylvain S   Brenner Matthew M   Durkin Anthony J AJ   Choi Bernard B   Tromberg Bruce J BJ  

Journal of biomedical optics 20180301 3


The tissue metabolic rate of oxygen consumption (tMRO2) is a clinically relevant marker for a number of pathologies including cancer and arterial occlusive disease. We present and validate a noncontact method for quantitatively mapping tMRO2 over a wide, scalable field of view at 16  frames  /  s. We achieve this by developing a dual-wavelength, near-infrared coherent spatial frequency-domain imaging (cSFDI) system to calculate tissue optical properties (i.e., absorption, μa, and reduced scatter  ...[more]

Similar Datasets

| S-EPMC5511354 | biostudies-literature
| S-EPMC8196160 | biostudies-literature
| S-EPMC3565969 | biostudies-literature
| S-EPMC8145383 | biostudies-literature
| S-EPMC6160429 | biostudies-literature
| S-EPMC3420008 | biostudies-literature
| S-EPMC6264385 | biostudies-other
| S-EPMC6486671 | biostudies-literature
| S-EPMC7427561 | biostudies-literature
| S-EPMC9804021 | biostudies-literature