Facile Quantification and Identification Techniques for Reducing Gases over a Wide Concentration Range Using a MOS Sensor in Temperature-Cycled Operation.


ABSTRACT: Dedicated methods for quantification and identification of reducing gases based on model-based temperature-cycled operation (TCO) using a single commercial MOS gas sensor are presented. During high temperature phases the sensor surface is highly oxidized, yielding a significant sensitivity increase after switching to lower temperatures (differential surface reduction, DSR). For low concentrations, the slope of the logarithmic conductance during this low-temperature phase is evaluated and can directly be used for quantification. For higher concentrations, the time constant for reaching a stable conductance during the same low-temperature phase is evaluated. Both signals represent the reaction rate of the reducing gas on the strongly oxidized surface at this low temperature and provide a linear calibration curve, which is exceptional for MOS sensors. By determining these reaction rates on different low-temperature plateaus and applying pattern recognition, the resulting footprint can be used for identification of different gases. All methods are tested over a wide concentration range from 10 ppb to 100 ppm (4 orders of magnitude) for four different reducing gases (CO, H?, ammonia and benzene) using randomized gas exposures.

SUBMITTER: Schultealbert C 

PROVIDER: S-EPMC5876710 | biostudies-literature | 2018 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Facile Quantification and Identification Techniques for Reducing Gases over a Wide Concentration Range Using a MOS Sensor in Temperature-Cycled Operation.

Schultealbert Caroline C   Baur Tobias T   Schütze Andreas A   Sauerwald Tilman T  

Sensors (Basel, Switzerland) 20180301 3


Dedicated methods for quantification and identification of reducing gases based on model-based temperature-cycled operation (TCO) using a single commercial MOS gas sensor are presented. During high temperature phases the sensor surface is highly oxidized, yielding a significant sensitivity increase after switching to lower temperatures (differential surface reduction, DSR). For low concentrations, the slope of the logarithmic conductance during this low-temperature phase is evaluated and can dir  ...[more]

Similar Datasets

| S-EPMC8382768 | biostudies-literature
| S-EPMC3228408 | biostudies-literature
| S-EPMC2972948 | biostudies-literature
| S-EPMC7309052 | biostudies-literature
| S-EPMC7967152 | biostudies-literature
| S-EPMC8271963 | biostudies-literature
| S-EPMC5879698 | biostudies-literature
| S-EPMC8660022 | biostudies-literature
| S-EPMC2976522 | biostudies-literature
| S-EPMC7876191 | biostudies-literature