Digital breast tomosynthesis for breast cancer screening and diagnosis in women with dense breasts - a systematic review and meta-analysis.


ABSTRACT: BACKGROUND:This study aimed to systematically review and to meta-analyse the accuracy of digital breast tomosynthesis (DBT) versus digital mammography (DM) in women with mammographically dense breasts in screening and diagnosis. METHODS:Two independent reviewers identified screening or diagnostic studies reporting at least one of four outcomes (cancer detection rate-CDR, recall rate, sensitivity and specificity) for DBT and DM in women with mammographically dense breasts. Study quality was assessed using QUADAS-2. Meta-analysis of CDR and recall rate used a random effects model. Summary ROC curve summarized sensitivity and specificity. RESULTS:Sixteen studies were included (five diagnostic; eleven screening). In diagnosis, DBT increased sensitivity (84%-90%) versus DM alone (69%-86%) but not specificity. DBT improved CDR versus DM alone (RR: 1.16, 95% CI 1.02-1.31). In screening, DBT?+?DM increased CDR versus DM alone (RR: 1.33, 95% CI 1.20-1.47 for retrospective studies; RR: 1.52, 95% CI 1.08-2.11 for prospective studies). Recall rate was significantly reduced by DBT?+?DM in retrospective studies (RR: 0.72, 95% CI 0.64-0.80) but not in two prospective studies (RR: 1.12, 95% CI 0.76-1.63). CONCLUSION:In women with mammographically dense breasts, DBT+/-DM increased CDR significantly (versus DM) in screening and diagnosis. In diagnosis, DBT+/-DM increased sensitivity but not specificity. The effect of DBT?+?DM on recall rate in screening dense breasts varied between studies.

SUBMITTER: Phi XA 

PROVIDER: S-EPMC5883365 | biostudies-literature | 2018 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Digital breast tomosynthesis for breast cancer screening and diagnosis in women with dense breasts - a systematic review and meta-analysis.

Phi Xuan-Anh XA   Tagliafico Alberto A   Houssami Nehmat N   Greuter Marcel J W MJW   de Bock Geertruida H GH  

BMC cancer 20180403 1


<h4>Background</h4>This study aimed to systematically review and to meta-analyse the accuracy of digital breast tomosynthesis (DBT) versus digital mammography (DM) in women with mammographically dense breasts in screening and diagnosis.<h4>Methods</h4>Two independent reviewers identified screening or diagnostic studies reporting at least one of four outcomes (cancer detection rate-CDR, recall rate, sensitivity and specificity) for DBT and DM in women with mammographically dense breasts. Study qu  ...[more]

Similar Datasets

| S-EPMC10067692 | biostudies-literature
| S-EPMC7276668 | biostudies-literature
| S-EPMC9222054 | biostudies-literature
| S-EPMC7434777 | biostudies-literature
| S-EPMC9276736 | biostudies-literature
| S-EPMC8168096 | biostudies-literature
| S-EPMC6795638 | biostudies-literature
| S-EPMC8683595 | biostudies-literature
| S-EPMC7153958 | biostudies-literature
| S-EPMC8102709 | biostudies-literature