Unknown

Dataset Information

0

Predicting delivery of a small-for-gestational-age infant and adverse perinatal outcome in women with suspected pre-eclampsia.


ABSTRACT:

Objective

To evaluate the test performance of 47 biomarkers and ultrasound parameters for the prediction of delivery of a small-for-gestational-age (SGA) infant and adverse perinatal outcome in women presenting with suspected pre-eclampsia.

Methods

This was a prospective, multicenter observational study in which 47 biomarkers and ultrasound parameters were measured in 397 women with a singleton pregnancy presenting with suspected preterm pre-eclampsia between 20 + 0 and 36 + 6 weeks' gestation, with the objective of evaluating them as predictors of subsequent delivery of a SGA infant and adverse perinatal outcome. Women with confirmed pre-eclampsia at enrollment were excluded. Factor analysis and stepwise logistic regression were performed in two prespecified groups stratified according to gestational age at enrollment. The primary outcome was delivery of a SGA infant with a birth weight < 3rd customized centile (SGA-3), and secondary outcomes were a SGA infant with a birth weight < 10th customized centile and adverse perinatal outcome.

Results

In 274 women presenting at 20 + 0 to 34 + 6 weeks' gestation, 96 (35%) delivered a SGA-3 infant. For prediction of SGA-3, low maternal placental growth factor (PlGF) concentration had a sensitivity of 93% (95% CI, 84-98%) and negative predictive value (NPV) of 90% (95% CI, 76-97%) compared with a sensitivity of 71% (95% CI, 58-82%) and a NPV of 79% (95% CI, 68-87%) for ultrasound parameters (estimated fetal weight or abdominal circumference < 10th centile). No individual biomarker evaluated had a better performance than did PlGF, and marker combinations made only small improvements to the test performance. Similar results were found in 123 women presenting between 35 + 0 and 36 + 6 weeks' gestation.

Conclusion

In women presenting with suspected preterm pre-eclampsia, measurement of PlGF offers a useful adjunct for identifying those at high risk of delivering a SGA infant, allowing appropriate surveillance and timely intervention. © 2017 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.

SUBMITTER: Griffin M 

PROVIDER: S-EPMC5887913 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC5837300 | biostudies-literature
| S-EPMC8074755 | biostudies-literature
| S-EPMC6771855 | biostudies-other
| S-EPMC5576505 | biostudies-literature
| S-EPMC5402970 | biostudies-literature