Comparison of activated clotting times measured using the Hemochron Jr. Signature and Medtronic ACT Plus during cardiopulmonary bypass with acute normovolemic haemodilution.


ABSTRACT: Objective This study compared the activated clotting time (ACT) measured using the Hemochron Jr. Signature (HACT) with the ACT measured using the Medtronic ACT Plus (MACT) during cardiopulmonary bypass (CPB) with acute normovolemic haemodilution (ANH) in patients undergoing cardiac surgery. Methods The ACT was checked at baseline with both devices after inducing anaesthesia, and 400 to 800 mL of whole blood was withdrawn to induce moderate ANH. Before initiating CPB, a 300-IU/kg bolus dose of heparin was administered to maintain the HACT at >400 s; protamine was later given to reverse the anticoagulation. The ACT was checked using both devices at baseline, during heparinisation, and after protamine administration. Results In total, 106 pairs of samples from 29 patients were analysed. The ACT showed a good correlation between the two devices (r?=?0.956). However, Bland-Altman analysis showed that the MACT was higher, particularly at baseline and during heparinisation. Multiple regression analysis showed that the blood glucose concentration significantly influenced the differences between the two ACT devices. Conclusions The HACT was lower than the MACT during CPB with ANH in patients undergoing cardiac surgery. Clinicians should be cautious when using each ACT device within generally accepted reference ACT values.

SUBMITTER: Lee JM 

PROVIDER: S-EPMC5971518 | biostudies-literature | 2018 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of activated clotting times measured using the Hemochron Jr. Signature and Medtronic ACT Plus during cardiopulmonary bypass with acute normovolemic haemodilution.

Lee Jung Min JM   Park Eun Young EY   Kim Kyung Mi KM   Won Jong Chan JC   Jung Tack Koon TK   Lee Soo Kyung SK  

The Journal of international medical research 20171004 2


Objective This study compared the activated clotting time (ACT) measured using the Hemochron Jr. Signature (HACT) with the ACT measured using the Medtronic ACT Plus (MACT) during cardiopulmonary bypass (CPB) with acute normovolemic haemodilution (ANH) in patients undergoing cardiac surgery. Methods The ACT was checked at baseline with both devices after inducing anaesthesia, and 400 to 800 mL of whole blood was withdrawn to induce moderate ANH. Before initiating CPB, a 300-IU/kg bolus dose of he  ...[more]

Similar Datasets

| S-EPMC7840648 | biostudies-literature
| S-EPMC9209891 | biostudies-literature
2010-05-27 | E-GEOD-924 | biostudies-arrayexpress
2003-12-20 | GSE924 | GEO
| S-EPMC10284479 | biostudies-literature
| S-EPMC4129556 | biostudies-literature
| S-EPMC4837010 | biostudies-literature
| S-EPMC6173634 | biostudies-literature
| S-EPMC9510884 | biostudies-literature
| S-EPMC7222340 | biostudies-literature