Unknown

Dataset Information

0

Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients.


ABSTRACT:

Background

The need for unobtrusive HR (heart rate) monitoring has led to the development of a new generation of strapless HR monitors. The aim of this study was to determine whether such an unobtrusive, wrist-worn optical HR monitor (OHRM) could be equivalent and therefore a valid alternative to a traditional chest strap during a broad range of activities in a heterogeneous healthy population and coronary artery disease (CAD) patients.

Methods

One hundred ninety-nine healthy volunteers, 84 males and 115 females, including 35 overweight-obese subjects, 53 pregnant women, and 20 CAD patients were tested in the present study. Second-by-second HR measured by the OHRM was concurrently evaluated against an ECG-based chest strap monitor during a broad range of activities (i.e., walking, running, cycling, gym, household, and sedentary activities).

Results

Data coverage, percentage of time the OHRM provides a HR not larger than 10 bpm from the reference, went from a minimum of 92% of the time in the least periodic activity (i.e., gym), to 95% during the most intense activity (i.e., running), and to a maximum of 98% for sedentary activities. The limits of agreement of the difference between the OHRM and the chest strap HR were within the range of ±15 bpm. The OHRM showed a concordance correlation coefficient of 0.98. Overall, the mean absolute error was not larger than 3 bpm, which can be considered clinically acceptable for a number of applications. A similar performance was found for CAD (94.2% coverage, 2.4 bpm error), but the small sample size does not allow any quantitative comparison.

Conclusion

Heart rate measured by OHRM at the wrist and ECG-based HR measured via a traditional chest strap are acceptably close in a broad range of activities in a heterogeneous, healthy population, and showed initial promising results also in CAD patients.

SUBMITTER: Sartor F 

PROVIDER: S-EPMC5984393 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients.

Sartor Francesco F   Gelissen Jos J   van Dinther Ralph R   Roovers David D   Papini Gabriele B GB   Coppola Giuseppe G  

BMC sports science, medicine & rehabilitation 20180531


<h4>Background</h4>The need for unobtrusive HR (heart rate) monitoring has led to the development of a new generation of strapless HR monitors. The aim of this study was to determine whether such an unobtrusive, wrist-worn optical HR monitor (OHRM) could be equivalent and therefore a valid alternative to a traditional chest strap during a broad range of activities in a heterogeneous healthy population and coronary artery disease (CAD) patients.<h4>Methods</h4>One hundred ninety-nine healthy volu  ...[more]

Similar Datasets

| S-EPMC8057382 | biostudies-literature
| S-EPMC9952291 | biostudies-literature
| S-EPMC6550265 | biostudies-literature
| S-EPMC6777285 | biostudies-literature
| S-EPMC5491979 | biostudies-literature
| S-EPMC10747116 | biostudies-literature
| S-EPMC6913722 | biostudies-literature
| S-EPMC10709028 | biostudies-literature
| S-EPMC9852147 | biostudies-literature
| S-EPMC9923693 | biostudies-literature