3D Printed Cardiovascular Patient Specific Phantoms Used for Clinical Validation of a CT-derived FFR Diagnostic Software.


ABSTRACT: Purpose:3D printed patient specific vascular models provide the ability to perform precise and repeatable benchtop experiments with simulated physiological blood flow conditions. This approach can be applied to CT-derived patient geometries to determine coronary flow related parameters such as Fractional Flow Reserve (FFR). To demonstrate the utility of this approach we compared bench-top results with non-invasive CT-derived FFR software based on a computational fluid dynamics algorithm and catheter based FFR measurements. Materials and Methods:Twelve patients for whom catheter angiography was clinically indicated signed written informed consent to CT Angiography (CTA) before their standard care that included coronary angiography (ICA) and conventional FFR (Angio-FFR). The research CTA was used first to determine CT-derived FFR (Vital Images) and second to generate patient specific 3D printed models of the aortic root and three main coronary arteries that were connected to a programmable pulsatile pump. Benchtop FFR was derived from pressures measured proximal and distal to coronary stenosis using pressure transducers. Results:All 12 patients completed the clinical study without any complication, and the three FFR techniques (Angio-FFR, CT-FFR, and Benchtop FFR) are reported for one or two main coronary arteries. The Pearson correlation among Benchtop FFR/Angio-FFR, CT-FFR/ Benchtop FFR, and CT-FFR/ Angio-FFR are 0.871, 0.877, and 0.927 respectively. Conclusions:3D printed patient specific cardiovascular models successfully simulated hyperemic blood flow conditions, matching invasive Angio-FFR measurements. This benchtop flow system could be used to validate CT-derived FFR diagnostic software, alleviating both cost and risk during invasive procedures.

SUBMITTER: Sommer KN 

PROVIDER: S-EPMC5994607 | biostudies-literature | 2018 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

3D Printed Cardiovascular Patient Specific Phantoms Used for Clinical Validation of a CT-derived FFR Diagnostic Software.

Sommer Kelsey N KN   Shepard Lauren L   Karkhanis Nitant Vivek NV   Iyer Vijay V   Angel Erin E   Wilson Michael F MF   Rybicki Frank J FJ   Mitsouras Dimitrios D   Rudin Stephen S   Ionita Ciprian N CN  

Proceedings of SPIE--the International Society for Optical Engineering 20180201


<h4>Purpose</h4>3D printed patient specific vascular models provide the ability to perform precise and repeatable benchtop experiments with simulated physiological blood flow conditions. This approach can be applied to CT-derived patient geometries to determine coronary flow related parameters such as Fractional Flow Reserve (FFR). To demonstrate the utility of this approach we compared bench-top results with non-invasive CT-derived FFR software based on a computational fluid dynamics algorithm  ...[more]

Similar Datasets

| S-EPMC4981152 | biostudies-literature
| S-EPMC8128791 | biostudies-literature
| S-EPMC8761984 | biostudies-literature
| S-EPMC6856980 | biostudies-literature
| S-EPMC9970939 | biostudies-literature
| S-EPMC6122815 | biostudies-literature
| S-EPMC7027021 | biostudies-literature
| S-EPMC7643145 | biostudies-literature
| S-EPMC10130753 | biostudies-literature
| S-EPMC10326083 | biostudies-literature