Unknown

Dataset Information

0

Lung and diaphragm ultrasound as predictors of success in weaning from mechanical ventilation.


ABSTRACT:

Background

Lung and diaphragm ultrasound methods have recently been introduced to predict the outcome of weaning from mechanical ventilation (MV). The aim of this study is to assess the reliability and accuracy of these techniques for predicting successful weaning in critically ill adults.

Methods

We conducted two studies: a cross-sectional interobserver agreement study between two sonographers and a prospective cohort study to assess the accuracy of lung and diaphragm ultrasound for predicting weaning and extubation outcome. For the interobserver agreement study, we included 50 general critical care patients who were consecutively admitted to the ICU. For the predictive accuracy study, we included consecutively 69 patients on MV who were ready for weaning. We assessed interobserver agreement of ultrasound measurements, using the weighted kappa coefficient for LUSm score (modified lung ultrasound score) and the intraclass correlation coefficient (ICC) and Bland-Altman method for TI (diaphragm thickening index). We assessed the predictive value of LUSm and TI in weaning outcome by plotting the corresponding ROC curves.

Results

We found adequate interobserver agreement for both LUSm (weighted kappa 0.95) and TI (ICC 0.78, difference according to Bland-Altman analysis?±?12.5%). LUSm showed good-moderate discriminative power for successful weaning and extubation (area under the ROC curve (AUC) for successful weaning 0.80, and sensitivity and specificity at optimal cut-off point 0.76 and 0.73, respectively; AUC for successful extubation 0.78, and optimal sensitivity and specificity 0.76 and 0.47, respectively. TI was more sensitive but less specific for predicting successful weaning (AUC 0.71, optimal sensitivity and specificity 0.93 and 0.48) and successful extubation (AUC 0.76, optimal sensitivity and specificity 0.93 and 0.58). The area under the ROC curve for predicting weaning success was 0.83 for both ultrasound measurements together.

Conclusions

Interobserver agreement was excellent for LUSm and moderate-good for TI. A low TI value or high LUSm value indicates high risk of weaning failure.

SUBMITTER: Tenza-Lozano E 

PROVIDER: S-EPMC6004341 | biostudies-literature | 2018 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Lung and diaphragm ultrasound as predictors of success in weaning from mechanical ventilation.

Tenza-Lozano Eva E   Llamas-Alvarez Ana A   Jaimez-Navarro Enrique E   Fernández-Sánchez Javier J  

Critical ultrasound journal 20180618 1


<h4>Background</h4>Lung and diaphragm ultrasound methods have recently been introduced to predict the outcome of weaning from mechanical ventilation (MV). The aim of this study is to assess the reliability and accuracy of these techniques for predicting successful weaning in critically ill adults.<h4>Methods</h4>We conducted two studies: a cross-sectional interobserver agreement study between two sonographers and a prospective cohort study to assess the accuracy of lung and diaphragm ultrasound  ...[more]

Similar Datasets

| S-EPMC5913054 | biostudies-literature
| S-EPMC9392990 | biostudies-literature
| S-EPMC5861656 | biostudies-literature
| S-EPMC10046995 | biostudies-literature
| S-EPMC7092676 | biostudies-literature
| S-EPMC7710325 | biostudies-literature
| S-EPMC6337771 | biostudies-literature
| S-EPMC9354572 | biostudies-literature
| S-EPMC6469194 | biostudies-literature