Unknown

Dataset Information

0

Rapid Identification and Simultaneous Quantification of Aristolochic Acids by HPLC-DAD and Confirmations by MS in Aristolochia chilensis Using a Limited Biomass.


ABSTRACT: Six aristolochic acids were identified in the Chilean species Aristolochia chilensis using high-performance liquid chromatography coupled to a diode array detector (HPLC-DAD) and subsequent confirmation with mass spectrometry (MS). The fractions of each signal were collected and injected directly into an Orbitrap mass detector model Q Exactive Focus (Thermo Scientific). The acids extraction was done with 0.10-0.50?g of lyophilized and pulverized sample and concentrated in Soxhlet extraction equipment. The liquid-liquid separations and a subsequent solid phase extraction (SPE) C18 were performed using 100?µL of the extract that contains the aristolochic acids present in the Aristolochia chilensis plant. The HPLC conditions used a single mobile phase acetonitrile?:?water (1?:?1) acidified with 0.1% acetic acid and an isocratic elution to 1?mL·min-1. The column InertSustain C18 250?×?4.6?mm and 3?µm was used, the injection volume was 20?µL, and the time of run was reduced to 15?min. Calibration curves were constructed with r2?being 0.9997. The quantification limit for AAI was 0.138?±?0.010?µg/mL, and for AAII, it was 0.558?±?0.042?µg/mL.

SUBMITTER: Araya M 

PROVIDER: S-EPMC6011054 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

Rapid Identification and Simultaneous Quantification of Aristolochic Acids by HPLC-DAD and Confirmations by MS in <i>Aristolochia chilensis</i> Using a Limited Biomass.

Araya Michael M   García Samantha S   González-Teuber Marcia M  

Journal of analytical methods in chemistry 20180606


Six aristolochic acids were identified in the Chilean species <i>Aristolochia chilensis</i> using high-performance liquid chromatography coupled to a diode array detector (HPLC-DAD) and subsequent confirmation with mass spectrometry (MS). The fractions of each signal were collected and injected directly into an Orbitrap mass detector model Q Exactive Focus (Thermo Scientific). The acids extraction was done with 0.10-0.50 g of lyophilized and pulverized sample and concentrated in Soxhlet extracti  ...[more]

Similar Datasets

| S-EPMC8153899 | biostudies-literature
| S-EPMC3640015 | biostudies-literature
| S-EPMC6151405 | biostudies-literature
| S-EPMC5052439 | biostudies-literature
| S-EPMC6720735 | biostudies-literature
| S-EPMC6630902 | biostudies-literature
| S-EPMC8400717 | biostudies-literature
| S-EPMC4129172 | biostudies-literature
| S-EPMC3602048 | biostudies-literature
| S-EPMC7278696 | biostudies-literature