Randomized Outpatient Trial of Single- and Dual-Hormone Closed-Loop Systems That Adapt to Exercise Using Wearable Sensors.


ABSTRACT: Automated insulin delivery is the new standard for type 1 diabetes, but exercise-related hypoglycemia remains a challenge. Our aim was to determine whether a dual-hormone closed-loop system using wearable sensors to detect exercise and adjust dosing to reduce exercise-related hypoglycemia would outperform other forms of closed-loop and open-loop therapy.Participants underwent four arms in randomized order: dual-hormone, single-hormone, predictive low glucose suspend, and continuation of current care over 4 outpatient days. Each arm included three moderate-intensity aerobic exercise sessions. The two primary outcomes were percentage of time in hypoglycemia (<70 mg/dL) and in a target range (70-180 mg/dL) assessed across the entire study and from the start of the in-clinic exercise until the next meal.The analysis included 20 adults with type 1 diabetes who completed all arms. The mean time (SD) in hypoglycemia was the lowest with dual-hormone during the exercise period: 3.4% (4.5) vs. 8.3% (12.6) single-hormone (P = 0.009) vs. 7.6% (8.0) predictive low glucose suspend (P < 0.001) vs. 4.3% (6.8) current care where pre-exercise insulin adjustments were allowed (P = 0.49). Time in hypoglycemia was also the lowest with dual-hormone during the entire 4-day study: 1.3% (1.0) vs. 2.8% (1.7) single-hormone (P < 0.001) vs. 2.0% (1.5) predictive low glucose suspend (P = 0.04) vs. 3.1% (3.2) current care (P = 0.007). Time in range during the entire study was the highest with single-hormone: 74.3% (8.0) vs. 72.0% (10.8) dual-hormone (P = 0.44).The addition of glucagon delivery to a closed-loop system with automated exercise detection reduces hypoglycemia in physically active adults with type 1 diabetes.

SUBMITTER: Castle JR 

PROVIDER: S-EPMC6014543 | biostudies-literature | 2018 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Randomized Outpatient Trial of Single- and Dual-Hormone Closed-Loop Systems That Adapt to Exercise Using Wearable Sensors.

Castle Jessica R JR   El Youssef Joseph J   Wilson Leah M LM   Reddy Ravi R   Resalat Navid N   Branigan Deborah D   Ramsey Katrina K   Leitschuh Joseph J   Rajhbeharrysingh Uma U   Senf Brian B   Sugerman Samuel M SM   Gabo Virginia V   Jacobs Peter G PG  

Diabetes care 20180511 7


<h4>Objective</h4>Automated insulin delivery is the new standard for type 1 diabetes, but exercise-related hypoglycemia remains a challenge. Our aim was to determine whether a dual-hormone closed-loop system using wearable sensors to detect exercise and adjust dosing to reduce exercise-related hypoglycemia would outperform other forms of closed-loop and open-loop therapy.<h4>Research design and methods</h4>Participants underwent four arms in randomized order: dual-hormone, single-hormone, predic  ...[more]

Similar Datasets

| S-EPMC3687268 | biostudies-literature
| S-EPMC4067397 | biostudies-literature
| S-EPMC8608837 | biostudies-literature
| S-EPMC5510043 | biostudies-literature
| S-EPMC8012332 | biostudies-literature
| S-EPMC9710866 | biostudies-literature
| S-EPMC9837268 | biostudies-literature
| S-EPMC6658323 | biostudies-literature
2022-10-14 | GSE215246 | GEO
| S-EPMC9315597 | biostudies-literature