Project description:We describe two false-negative results in the detection of meticillin-resistant Staphylococcus aureus (MRSA) of sequence type 398 and spa type t011 using the Cepheid Xpert MRSA NxG assay. The isolates were recovered in late February and early March 2021 from two patients in different hospitals in the northern Netherlands. Variations between the two isolate genomes indicate that this MRSA strain might have been spreading for some time and could have disseminated to other regions of the Netherlands and other European countries.
Project description:BackgroundPositive blood cultures showing Gram positive cocci in clusters signifies either Staphylococcus aureus or the less-virulent coagulase-negative staphylococci. Rapid identification and methicillin susceptibility determination with the Xpert MRSA/SA BC assay can improve management of S. aureus bloodstream infection and reduce inappropriate antibiotic use.MethodsWe prospectively evaluated the Xpert MRSA/SA BC assay in comparison with culture, on samples referred to our laboratory in the Western Cape, South Africa. We interviewed attending clinicians upon culture result availability, to assess antibiotic choices and estimate potential impact of the assay.ResultsOf the 231 samples included, there was 100% concordance between the Xpert MRSA/SA BC assay and culture (methicillin-resistant S. aureus 15/15, methicillin-susceptible S. aureus 42/42, coagulase-negative staphylococci 170/170). Time to final result could be reduced by approximately 30 h with the assay. Of the 178 patients with adequate antibiotic history, optimisation of antistaphylococcal therapy could have occurred more than 1 day sooner in 68.9% with S. aureus bloodstream infection (31/45, 95% CI 53.2-81.4%). Six of the 11 patients with methicillin-resistant S. aureus bloodstream infection (54.5%) could have received anti-MRSA cover sooner. Fifty-four days of antibiotic therapy could have been spared, equating to 0.3 days (95% CI, 0.2-0.4) saved per patient, driven by broad-spectrum beta-lactams (32 days, in 18.0% of the cohort).ConclusionThis assay has potential as an antimicrobial stewardship tool; costing and impact on clinical outcome in patients with S. aureus bloodstream infection should be assessed.
Project description:IntroductionRapid identification of the causal organism and antibiotic resistance is crucial for guiding targeted therapy in patients with suspected staphylococcal infection. A meta-analysis was carried out to evaluate the diagnostic relevance of Xpert™ MRSA/SA (Xpert) from clinical samples of various origins for limiting the use of unnecessary empirical methicillin-resistant Staphylococcus aureus (MRSA) therapy.MethodsFive databases, including the Cochrane Library, Scopus, PubMed, Web of Science, and Embase, were comprehensively inspected from inception to October 12, 2021. The pooled summary estimates were evaluated using a bivariate random-effects model.ResultsOur inclusion criteria were met by 49 publications containing 68 datasets out of 735 citations. A total of 21 studies (n = 4996) examined the accuracy of Xpert in detecting methicillin-sensitive S. aureus (MSSA), while 47 studies (n = 45,430) examined the accuracy of Xpert in detecting MRSA. As compared to MRSA, Xpert's diagnostic performance for MSSA detection was markedly higher [sensitivity: 0.97 (0.96-0.98), specificity: 0.97 (0.97-0.98), area under curve (AUC): 0.99 (0.99-1.0)]. Xpert's pooled sensitivity and specificity differed marginally across sample types, including screening of colonization, lower respiratory tract (LRT), osteoarticular, and bloodstream samples. Notably, the Xpert pooled specificity was consistently ≥ 92% against microbiological culture across all sample types. The diagnostic efficiency heterogeneity was not explained by a meta-regression and subgroup analysis of research design, sample conditions, and sampling methods (P > 0.05).ConclusionOur findings suggest that Xpert could be used as the favoured screening test for the early detection of staphylococcal infection in a variety of sample types, with the goal of guiding therapeutic decisions.
Project description:The Cepheid Xpert® Xpress SARS-CoV-2 assay is 1 of the several real-time reverse transcription polymerase chain reaction (RT-PCR) assays that received Emergency Use Authorization from the United States Food and Drug Administration (FDA) for detection of SARS-CoV-2. Here we report 4 SARS-CoV-2 samples that were reported as presumptive positives on the Cepheid platform while reported as positives on alternative RT-PCR platforms. Whole genome sequencing indicated that the samples were Delta variants and had point mutations in the N gene which potentially interfered with SARS-CoV-2 detection. Two types of point mutations were found in these samples in the US CDC 2019-nCoV Real time PCR N2 Probe region: C29203T and C29200T. C29203T is a novel point mutation, and C29200T has not been previously reported in the Delta variants. This underlines the fact that mutations in the real-time RT-PCR assay target region could hinder accurate detection of SARS-CoV-2.
Project description:An advanced methicillin-resistant Staphylococcus aureus (MRSA) detection PCR approach targeting SCCmec-orfX along with mecA and mecC was evaluated for S. aureus and coagulase-negative staphylococci. The possession of mecA and/or mecC was correctly confirmed in all cases. All methicillin-susceptible S. aureus strains (n = 98; including staphylococcal cassette chromosome mec element [SCCmec] remnants) and 98.1% of the MRSA strains (n = 160, including 10 mecC-positive MRSA) were accurately categorized.
Project description:The coronavirus disease 2019 (Covid-19) pandemic, caused by SARS-CoV-2, has resulted in a global testing supply shortage. In response, pooled testing has emerged as a promising strategy that can immediately increase testing capacity. In pooled sample testing, multiple samples are combined (or pooled) together and tested as a single unit. If the pool is positive, the individual samples can then be individually tested to identify the positive case(s). Here, we provide support for the adoption of sample pooling with the point-of-care Cepheid Xpert® Xpress SARS-CoV-2 molecular assay. Corroborating previous findings, the limit of detection of this assay was comparable to laboratory-developed reverse-transcription quantitative PCR SARS-CoV-2 tests, with observed detection below 100 copies/mL. The Xpert® Xpress assay detected SARS-CoV-2 after samples with minimum viral loads of 461 copies/mL were pooled in groups of six. Based on these data, we recommend the adoption of pooled testing with the Xpert® Xpress SARS-CoV-2 assay where warranted based on public health needs. The suggested number of samples per pool, or the pooling depth, is unique for each point-of-care testing site and can be determined by the positive test rates. To statistically determine appropriate pooling depth, we have calculated the pooling efficiency for numerous combinations of pool sizes and test rates. This information is included as a supplemental dataset that we encourage public health authorities to use as a guide to make recommendations that will maximize testing capacity and resource conservation.
Project description:Early in the Severe Acute Respiratory Syndrome Coronavirus 2 pandemic, there was a progressive increase in diagnostic demands that developed within a relatively short period of time. On February 4, 2020, the Secretary of Health and Human Services issued the Emergency Use Authorization for in vitro diagnostics assays for the Severe Acute Respiratory Syndrome Coronavirus 2 virus. Subsequently, multiple assays were approved under the Emergency Use Authorization, including the Cepheid Xpert SARS-CoV-2 assay. Presented here is a description of the nationally coordinated verification study of the Cepheid assay that was performed within the Veteran's Affairs Health System. This coordinated study helped to expedite the verification process for a majority of the Veteran's Affairs system labs, preserved precious system resources, and highlighted the power of a national medical system in response to an emergency.
Project description:BackgroundXpert MTB/RIF ("Xpert") is a molecular test for detection of Mycobacterium tuberculosis (MTB) in sputum. Performance characteristics have been established for its use during passive tuberculosis (TB) case detection in symptomatic TB suspects, but Xpert performance has not been assessed in other settings. Objectives were to determine Xpert performance and costs in the context of a TB prevalence survey.Methodology/principal findingsThis was a diagnostic sub-study of a TB prevalence survey conducted in gold mining companies in South Africa. Sputa (one per participant) were tested using smear microscopy, liquid culture (reference comparator), and Xpert. Costs were collected using an ingredients approach and analyzed using a public health program perspective. 6893 participants provided a sputum specimen. 187/6893 (2.7%) were positive for MTB in culture, 144/6893 (2.1%) were positive for MTB by Xpert, and 91/6893 (1.3%) were positive for acid fast bacilli by microsocopy. Sensitivity, specificity, positive predictive value, and negative predictive value for detection of MTB by Xpert were 62.6% (95% confidence interval [CI] 55.2, 69.5), 99.6% (99.4, 99.7), 81.3% (73.9, 87.3), and 98.9 (98.6, 98.8); agreement between Xpert and culture was 98.5% (98.2, 98.8). Sensitivity of microscopy was 17.6% (12.5, 23.9). When individuals with a history of TB treatment were excluded from the analysis, Xpert specificity was 99.8 (99.7, 99.9) and PPV was 90.6 (83.3, 95.4) for detection of MTB. For the testing scenario of 7000 specimens with 2.7% of specimens culture positive for MTB, costs were $165,690 for Xpert and $115,360 for the package of microscopy plus culture.ConclusionIn the context of a TB prevalence survey, the Xpert diagnostic yield was substantially higher than that of microscopy yet lower than that of liquid culture. Xpert may be useful as a sole test for TB case detection in prevalence surveys, particularly in settings lacking capacity for liquid culture.
Project description:Tests for Chlamydia trachomatis and Neisseria gonorrhoeae, which can provide results rapidly to guide therapeutic decision-making, offer patient care advantages over laboratory-based tests that require several days to provide results. We compared results from the Cepheid GeneXpert CT/NG (Xpert) assay to results from two currently approved nucleic acid amplification assays in 1,722 female and 1,387 male volunteers. Results for chlamydia in females demonstrated sensitivities for endocervical, vaginal, and urine samples of 97.4%, 98.7%, and 97.6%, respectively, and for urine samples from males, a sensitivity of 97.5%, with all specificity estimates being ? 99.4%. Results for gonorrhea in females demonstrated sensitivities for endocervical, vaginal, and urine samples of 100.0%, 100.0%, and 95.6%, respectively, and for urine samples from males, a sensitivity of 98.0%, with all estimates of specificity being ? 99.8%. These results indicate that this short-turnaround-time test can be used to accurately test patients and to possibly do so at the site of care, thus potentially improving chlamydia and gonorrhea control efforts.