Aortic root evaluation prior to transcatheter aortic valve implantation-Correlation of manual and semi-automatic measurements.


ABSTRACT: BACKGROUND:Pre-procedural TAVI planning requires highly sophisticated and time-consuming manual measurements performed by experienced readers. Semi-automatic software may assist with partial automation of assessment of multiple parameters. The aim of this study was to evaluate differences between manual and semi-automatic measurements in terms of agreement and time. METHODS:One hundred and twenty TAVI candidates referred for the retrospectively ECG-gated CTA (2nd and 3rd generation dual source CT) were evaluated. Fully manual and semi-automatic measurements of fourteen aortic root parameters were assessed in the 20% phase of the R-R interval. Reading time was compared using paired samples t-test. Inter-software agreement was calculated using the Intraclass correlation coefficient (ICC) in a 2-way mixed effects model. Differences between manual and semi-automatic measurements were evaluated using Bland-Altman analysis. RESULTS:The time needed for evaluation using semi-automatic assessment (3 min 24 s ± 1 min 7 s) was significantly lower (p<0.001) compared to a fully manual approach (6 min 31 sec ± 1 min 1 sec). Excellent inter-software agreement was found (ICC = 0.93 ± 0.0; range:0.90-0.95). The same prosthesis size from manual and semi-automatic measurements was selected in 92% of cases, when sizing was based on annular area. Prosthesis sizing based on annular short diameter and perimeter agreed in 99% and 96% cases, respectively. CONCLUSION:Use of semi-automatic software in pre-TAVI evaluation results in comparable results in respect of measurements and selected valve prosthesis size, while necessary reading time is significantly lower.

SUBMITTER: Horehledova B 

PROVIDER: S-EPMC6023104 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

Aortic root evaluation prior to transcatheter aortic valve implantation-Correlation of manual and semi-automatic measurements.

Horehledova Barbora B   Mihl Casper C   Schwemmer Chris C   Hendriks Babs M F BMF   Eijsvoogel Nienke G NG   Kietselaer Bastiaan L J H BLJH   Wildberger Joachim E JE   Das Marco M  

PloS one 20180628 6


<h4>Background</h4>Pre-procedural TAVI planning requires highly sophisticated and time-consuming manual measurements performed by experienced readers. Semi-automatic software may assist with partial automation of assessment of multiple parameters. The aim of this study was to evaluate differences between manual and semi-automatic measurements in terms of agreement and time.<h4>Methods</h4>One hundred and twenty TAVI candidates referred for the retrospectively ECG-gated CTA (2nd and 3rd generatio  ...[more]

Similar Datasets

| S-EPMC10583539 | biostudies-literature
| S-EPMC5808664 | biostudies-literature
| S-EPMC7890286 | biostudies-literature
| S-EPMC6242924 | biostudies-literature
| S-EPMC9390526 | biostudies-literature
| S-EPMC5639230 | biostudies-literature
| S-EPMC8183662 | biostudies-literature
| S-EPMC6727651 | biostudies-literature
| S-EPMC7066806 | biostudies-literature
| S-EPMC5479725 | biostudies-literature