Ontology highlight
ABSTRACT: Purpose
The aim of the study was to evaluate the role of high b-value (2000 sec/mm2) diffusion-weighted imaging (DWI) by using Readout Segmentation of Long Variable Echo-trains (RESOLVE) in differentiating papillary thyroid carcinomas (PTCs) and papillary thyroid microcarcinomas (PTMCs) from benign thyroid nodules.Materials and methods
Consecutive patients with thyroid nodules scheduled for surgery underwent high b-value DWI with 3 b-values: 0, 800 and 2000 sec/mm2. Signal intensity ratios (SIRs) of thyroid nodules to adjacent normal thyroid tissue on DWI were measured as: SIRb0, SIRb800 and SIRb2000. Apparent diffusion coefficient (ADC) values based on the 3 different b-values were acquired as: ADCb0-800, ADCb0-2000, and ADCb0-800-2000. The 6 diagnostic indicators were evaluated by receiver operating characteristic (ROC) and diagnostic ability was compared between high b-value DWI and Ultrasound (US).Results
A total of 52 PTCs including 33 PTMCs (38 patients, 8 men and 30 women, aged 45.68 ± 11.93 years) and 62 benign thyroid nodules (46 patients, 7 men and 39 women, aged 48.73 ± 11.98 years) were enrolled into the final statistical analysis. ADCb0-800-2000 had the highest diagnostic ability in differentiating PTCs from benign thyroid nodules with area under curve (AUC) of 0.944, sensitivity of 96.15% and specificity of 85.48%, and PTMCs from benign thyroid nodules with AUC of 0.940, sensitivity of 93.94% and specificity of 85.48%. On the strength of lower false-positive rates than US (14.52% vs. 32.26% for PTCs and 14.52% vs. 32.26% for PTMCs), ADCb0-800-2000 had significantly better diagnostic ability in PTCs (P = 0.002) and PTMCs (P = 0.005).Conclusion
High b-value (2000 sec/mm2) DWI can contribute to differentiating PTCs and PTMCs from benign thyroid nodules and can be potentially used as an active surveillance imaging method for PTMCs.
SUBMITTER: Wang Q
PROVIDER: S-EPMC6051619 | biostudies-literature | 2018
REPOSITORIES: biostudies-literature
Wang Qingjun Q Guo Yong Y Zhang Jing J Shi Lijing L Ning Haoyong H Zhang Xiliang X Lu Yuanyuan Y
PloS one 20180718 7
<h4>Purpose</h4>The aim of the study was to evaluate the role of high b-value (2000 sec/mm2) diffusion-weighted imaging (DWI) by using Readout Segmentation of Long Variable Echo-trains (RESOLVE) in differentiating papillary thyroid carcinomas (PTCs) and papillary thyroid microcarcinomas (PTMCs) from benign thyroid nodules.<h4>Materials and methods</h4>Consecutive patients with thyroid nodules scheduled for surgery underwent high b-value DWI with 3 b-values: 0, 800 and 2000 sec/mm2. Signal intens ...[more]