Molecularly selective nanoporous membrane-based wearable organic electrochemical device for noninvasive cortisol sensing.


ABSTRACT: Wearable biosensors have emerged as an alternative evolutionary development in the field of healthcare technology due to their potential to change conventional medical diagnostics and health monitoring. However, a number of critical technological challenges including selectivity, stability of (bio)recognition, efficient sample handling, invasiveness, and mechanical compliance to increase user comfort must still be overcome to successfully bring devices closer to commercial applications. We introduce the integration of an electrochemical transistor and a tailor-made synthetic and biomimetic polymeric membrane, which acts as a molecular memory layer facilitating the stable and selective molecular recognition of the human stress hormone cortisol. The sensor and a laser-patterned microcapillary channel array are integrated in a wearable sweat diagnostics platform, providing accurate sweat acquisition and precise sample delivery to the sensor interface. The integrated devices were successfully used with both ex situ methods using skin-like microfluidics and on human subjects with on-body real-sample analysis using a wearable sensor assembly.

SUBMITTER: Parlak O 

PROVIDER: S-EPMC6054510 | biostudies-literature | 2018 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Molecularly selective nanoporous membrane-based wearable organic electrochemical device for noninvasive cortisol sensing.

Parlak Onur O   Parlak Onur O   Keene Scott Tom ST   Marais Andrew A   Curto Vincenzo F VF   Salleo Alberto A  

Science advances 20180720 7


Wearable biosensors have emerged as an alternative evolutionary development in the field of healthcare technology due to their potential to change conventional medical diagnostics and health monitoring. However, a number of critical technological challenges including selectivity, stability of (bio)recognition, efficient sample handling, invasiveness, and mechanical compliance to increase user comfort must still be overcome to successfully bring devices closer to commercial applications. We intro  ...[more]

Similar Datasets

| S-EPMC8730602 | biostudies-literature
| S-EPMC4287724 | biostudies-other
| S-EPMC7083607 | biostudies-literature
| S-EPMC5375856 | biostudies-literature
| S-EPMC4451844 | biostudies-other
| S-EPMC9599184 | biostudies-literature
| S-EPMC6022123 | biostudies-literature
| S-EPMC9542454 | biostudies-literature
| S-EPMC10377510 | biostudies-literature
| S-EPMC9386496 | biostudies-literature