Unknown

Dataset Information

0

Electromyography-Driven Forward Dynamics Simulation to Estimate In Vivo Joint Contact Forces During Normal, Smooth, and Bouncy Gaits.


ABSTRACT: Computational models that predict in vivo joint loading and muscle forces can potentially enhance and augment our knowledge of both typical and pathological gaits. To adopt such models into clinical applications, studies validating modeling predictions are essential. This study created a full-body musculoskeletal model using data from the "Sixth Grand Challenge Competition to Predict in vivo Knee Loads." This model incorporates subject-specific geometries of the right leg in order to concurrently predict knee contact forces, ligament forces, muscle forces, and ground contact forces. The objectives of this paper are twofold: (1) to describe an electromyography (EMG)-driven modeling methodology to predict knee contact forces and (2) to validate model predictions by evaluating the model predictions against known values for a patient with an instrumented total knee replacement (TKR) for three distinctly different gait styles (normal, smooth, and bouncy gaits). The model integrates a subject-specific knee model onto a previously validated generic full-body musculoskeletal model. The combined model included six degrees-of-freedom (6DOF) patellofemoral and tibiofemoral joints, ligament forces, and deformable contact forces with viscous damping. The foot/shoe/floor interactions were modeled by incorporating shoe geometries to the feet. Contact between shoe segments and the floor surface was used to constrain the shoe segments. A novel EMG-driven feedforward with feedback trim motor control strategy was used to concurrently estimate muscle forces and knee contact forces from standard motion capture data collected on the individual subject. The predicted medial, lateral, and total tibiofemoral forces represented the overall measured magnitude and temporal patterns with good root-mean-squared errors (RMSEs) and Pearson's correlation (p2). The model accuracy was high: medial, lateral, and total tibiofemoral contact force RMSEs?=?0.15, 0.14, 0.21 body weight (BW), and (0.92?

SUBMITTER: Razu SS 

PROVIDER: S-EPMC6056185 | biostudies-literature | 2018 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Electromyography-Driven Forward Dynamics Simulation to Estimate In Vivo Joint Contact Forces During Normal, Smooth, and Bouncy Gaits.

Razu Swithin S SS   Guess Trent M TM  

Journal of biomechanical engineering 20180701 7


Computational models that predict in vivo joint loading and muscle forces can potentially enhance and augment our knowledge of both typical and pathological gaits. To adopt such models into clinical applications, studies validating modeling predictions are essential. This study created a full-body musculoskeletal model using data from the "Sixth Grand Challenge Competition to Predict in vivo Knee Loads." This model incorporates subject-specific geometries of the right leg in order to concurrentl  ...[more]

Similar Datasets

| S-EPMC9700656 | biostudies-literature
| S-EPMC3766202 | biostudies-literature
| S-EPMC4885751 | biostudies-literature
| S-EPMC6252115 | biostudies-literature
| S-EPMC5930183 | biostudies-literature
| S-EPMC2291359 | biostudies-literature
| S-EPMC5952297 | biostudies-literature
| S-EPMC4690839 | biostudies-other
| S-EPMC7083896 | biostudies-literature
| S-EPMC5882714 | biostudies-literature