High sensitivity organic inorganic hybrid X-ray detectors with direct transduction and broadband response.


ABSTRACT: X-ray detectors are critical to healthcare diagnostics, cancer therapy and homeland security, with many potential uses limited by system cost and/or detector dimensions. Current X-ray detector sensitivities are limited by the bulk X-ray attenuation of the materials and consequently necessitate thick crystals (~1?mm-1?cm), resulting in rigid structures, high operational voltages and high cost. Here we present a disruptive, flexible, low cost, broadband, and high sensitivity direct X-ray transduction technology produced by embedding high atomic number bismuth oxide nanoparticles in an organic bulk heterojunction. These hybrid detectors demonstrate sensitivities of 1712?µC?mGy-1?cm-3 for "soft" X-rays and ~30 and 58?µC?mGy-1?cm-3 under 6 and 15 MV "hard" X-rays generated from a medical linear accelerator; strongly competing with the current solid state detectors, all achieved at low bias voltages (-10 V) and low power, enabling detector operation powered by coin cell batteries.

SUBMITTER: Thirimanne HM 

PROVIDER: S-EPMC6062530 | biostudies-literature | 2018 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

High sensitivity organic inorganic hybrid X-ray detectors with direct transduction and broadband response.

Thirimanne H M HM   Jayawardena K D G I KDGI   Parnell A J AJ   Bandara R M I RMI   Karalasingam A A   Pani S S   Huerdler J E JE   Lidzey D G DG   Tedde S F SF   Nisbet A A   Mills C A CA   Silva S R P SRP  

Nature communications 20180726 1


X-ray detectors are critical to healthcare diagnostics, cancer therapy and homeland security, with many potential uses limited by system cost and/or detector dimensions. Current X-ray detector sensitivities are limited by the bulk X-ray attenuation of the materials and consequently necessitate thick crystals (~1 mm-1 cm), resulting in rigid structures, high operational voltages and high cost. Here we present a disruptive, flexible, low cost, broadband, and high sensitivity direct X-ray transduct  ...[more]

Similar Datasets

| S-EPMC6643692 | biostudies-literature
| S-EPMC6343061 | biostudies-literature
| S-EPMC8365385 | biostudies-literature
| S-EPMC5595872 | biostudies-other
| S-EPMC5423391 | biostudies-literature
| S-EPMC6804868 | biostudies-other
| S-EPMC9503050 | biostudies-literature
| S-EPMC5453346 | biostudies-other
| S-EPMC5455925 | biostudies-other
| S-EPMC4794706 | biostudies-other