Project description:Various strategies for improving reliability of fascicle identification on ultrasound images are used in practice, yet these strategies are untested for effectiveness. Studies suggest that the largest part of differences between fascicle lengths on one image are attributed to the error on the initial image. In this study, we compared reliability results between different strategies.Static single-image recordings and image sequence recordings during passive ankle rotations of the medial gastrocnemius were collected. Images were tracked by three different raters. We compared results from uninformed fascicle identification (UFI) and results with information from dynamic length changes, or data-informed tracking (DIT). A second test compared tracking of image sequences of either fascicle shortening (initial-long condition) or fascicle lengthening (initial-short condition).Intra-class correlations (ICC) were higher for the DIT compared to the UFI, yet yielded similar standard error of measurement (SEM) values. Between the initial-long and initial-short conditions, similar ICC values, coefficients of multiple determination, mean squared errors, offset-corrected mean squared errors and fascicle length change values were found for the DIT, yet with higher SEM values and greater absolute fascicle length differences between raters on the first image in the initial-long condition and on the final image in the initial-short condition.DIT improves reliability of fascicle length measurements, without lower SEM values. Fascicle length on the initial image has no effect on subsequent tracking results. Fascicles on ultrasound images should be identified by a single rater and care should be taken when comparing absolute fascicle lengths between studies.
Project description:BackgroundThe femoral canal is frequently measured preoperatively in cases where an intramedullary device is planned for operative fixation of a fracture. To our knowledge, a formal assessment of validity and reliability of preoperative canal measurements has not been previously performed.Questions/purposesThis study aims to determine the validity and reliability of preoperative canal measurements of the femur made on plain radiographs using comparison with curved planar reformation software as the gold standard.MethodsFifty-six patients were identified based on availability of anterior-posterior (AP) and lateral radiographs of the femur and computed tomography (CT) of the lower extremity. Four "raters" measured the canal diameter at its narrowest point and the distance from the lesser trochanter to the isthmus on the AP, lateral radiograph, and CT. The width of the femoral nail on AP radiographs was also measured to determine magnification error. Curved planar reformation (CPR) was used to provide the most accurate calculation of the canal diameter.ResultsCompared to the isthmus position determined by CPR, the measurement was most accurate on an AP and the diameter of the canal was most accurate using coronal CT, followed by AP radiographs. The measured canal diameter of the fractured femur on APs was compared to that of the used implant and varied by 1 mm.Discussion/conclusionThe AP plain radiographic measurement was found to be more accurate for determination of the canal diameter compared to the lateral radiograph. These findings confirm the utility of preoperative canal measurements in predicting the feasibility of placing a specific size intramedullary implant.
Project description:Pectoralis minor muscle length is believed to play an important role in shoulder pain and dysfunction. Current clinical procedures for assessing pectoralis minor muscle length may not provide the most useful information for clinical decision making.To establish the reliability and construct validity of a novel technique to measure pectoralis minor muscle length under actively and passively lengthened conditions.Cross-sectional repeated measures.Thirty-four healthy adults (age: 23.9, SD=1.6 years; 18 females) participated in this study. Pectoralis minor muscle length was measured on the dominant arm in three length conditions: resting, actively lengthened, and passively lengthened. Based upon availability, two raters, out of a pool of five, used a caliper to measure the distance between the coracoid process and the 4th rib. The average of two pectoralis minor muscle length measures was used for all muscle length conditions and analyses. Intraclass correlation coefficients determined intra-and inter-rater reliability, and measurement error was determined via standard error of measurement and minimal detectable change. Construct validity was assessed by ANOVA to determine differences in muscle length across the three conditions.Our intra- and inter-rater reliability values across all three conditions ranged from 0.84 to 0.92 and from 0.80 to 0.90, respectively. Significant differences (p<0.001) in muscle length were found among all three conditions: rest-active (3.66; SD=1.36cm), rest-passive (4.72, SD=1.41cm), and active-passive (1.06, SD=0.47cm).The techniques described in this study for measuring pectoralis minor muscle length under resting and actively and passively lengthened conditions have acceptable reliability for clinical decision making.
Project description:The cervical range of motion device (CROM) has been shown to provide reliable forward head position (FHP) measurement when the upper cervical angle (UCA) is controlled. However, measurement without UCA standardization is reflective of habitual patterns. Criterion validity has not been reported. The purposes of this study were to establish: (1) criterion validity of CROM FHP and UCA compared to Optotrak data, (2) relative reliability and minimal detectable change (MDC95) in patients with and without cervical pain, and (3) to compare UCA and FHP in patients with and without pain in habitual postures.(1) Within-subjects single session concurrent criterion validity design. Simultaneous CROM and OP measurement was conducted in habitual sitting posture in 16 healthy young adults. (2) Reliability and MDC95 of UCA and FHP were calculated from three trials. (3) Values for adults over 35 years with cervical pain and age-matched healthy controls were compared.(1) Forward head position distances were moderately correlated and UCA angles were highly correlated. The mean (standard deviation) differences can be expected to vary between 1·48 cm (1·74) for FHP and -1·7 (2·46)° for UCA. (2) Reliability for CROM FHP measurements were good to excellent (no pain) and moderate (pain). Cervical range of motion FHP MDC95 was moderately low (no pain), and moderate (pain). Reliability for CROM UCA measurements was excellent and MDC95 low for both groups. There was no difference in FHP distances between the pain and no pain groups, UCA was significantly more extended in the pain group (P<0·05).Cervical range of motion FHP measurements were only moderately correlated with Optotrak data, and limits of agreement (LOA) and MDC95 were relatively large. There was also no difference in CROM FHP distance between older symptomatic and asymptomatic individuals. Cervical range of motion FHP measurement is therefore not recommended as a clinical outcome measure. Cervical range of motion UCA measurements showed good criterion validity, excellent test-retest reliability, and achievable MDC95 in asymptomatic and symptomatic participants. Differences of more than 6° are required to exceed error. Cervical range of motion UCA shows promise as a useful reliable and valid measurement, particularly as patients with cervical pain exhibited significantly more extended angles.
Project description:BackgroundTelomere length (TL) is considered a biological marker of aging and may indicate age-related disease susceptibility. Adults and children show a fixed ranking and tracking of TL over time. However, the contribution of an individual's initial birth TL to their later life TL is unknown. We evaluated change and tracking of TL from birth to child- and adulthood.MethodsTelomere length at birth was measured using qPCR in two independent prospective birth cohorts. After a median follow-up period of 4 years in ENVIRONAGE (n = 273) we assessed leukocyte telomere length (LTL) and after 23 years in EFPTS (n = 164) buccal TL was assessed. Correlations and multivariable regression models were applied to study telomere tracking and determinants of TL change from birth onwards.FindingsIn children, LTL at the age of 4 correlates with TL at the start of life both in cord blood (r = 0.71, P < 0.0001;) and placenta (r = 0.60, P < 0.0001) and was -11.2% and -33.1% shorter, respectively. In adulthood, buccal TL at the age of 23 correlates with placental TL (r = 0.46, P < 0.0001) and was -35.9% shorter. TL attrition was higher in individuals with longer birth TL. However, based on TL ranking, individuals do not tend to change dramatically from TL rank after 4 or 23 years of follow-up. Finally, longer maternal TL associates with lower telomere attrition in the next generation.InterpretationThe high prediction of newborn TL for later life TL, and stable TL ranking from birth onwards underscores the importance of understanding the initial setting of newborn TL and its significance for later life.FundingEuropean Research Council (ERC-StG310898) and Flemish Scientific Fund (12X9620N).
Project description:Technical challenges associated with telomere length (TL) measurements have prompted concerns regarding their utility as a biomarker of aging. Several factors influence TL assessment via qPCR, the most common measurement method in epidemiological studies, including storage conditions and DNA extraction method. Here, we tested the impact of power supply during the qPCR assay. Momentary fluctuations in power can affect the functioning of high-performance electronics, including real-time thermocyclers. We investigated if mitigating these fluctuations by using an uninterruptible power supply (UPS) influenced TL assessment via qPCR. Samples run with a UPS had significantly lower standard deviation (p < 0.001) and coefficient of variation (p < 0.001) across technical replicates than those run without a UPS. UPS usage also improved exponential amplification efficiency at the replicate, sample, and plate levels. Together these improvements translated to increased performance across metrics of external validity including correlation with age, within-person correlation across tissues, and correlation between parents and offspring.
Project description:BackgroundA patient's physical function plays a leading role in the treatment prescription for patients with cancer. Objective assessments of physical function may be more predictive for treatment tolerability and survival than frequently used subjective measures, such as the Eastern Cooperative Oncology Group/World Health Organization (ECOG/WHO) performance score. The use of smartphones to measure physical activity and fitness may provide an excellent opportunity to objectively estimate a patient's physical function against low costs and little time. We investigated feasibility, validity and reliability of smartphone measurements of step count and physical fitness in patients with cancer.MethodsIn total, 72 patients participated. They wore a smartphone for 14 days to measure the mean number of steps per day, concomitant with an accelerometer during the first 7 days. Patients performed a six-minute walk test (6MWT) twice outdoors via a smartphone application and once in a test environment in the hospital. Feasibility was evaluated by the proportion of patients who completed the study as well as smartphone assessments of step count and physical fitness. Validity was assessed with the intraclass correlation coefficient (ICC) between the accelerometer and the first week of the smartphone for step count, and between the 6MWT in the hospital and via the application for physical fitness. Test-retest reliability was assessed with the ICC between step count levels of the first and second week of smartphone assessments, and between the first and second six-minute walk test in the home environment.ResultsThe completeness of smartphone measurements was approximately 90% for step count and 64% for physical fitness assessments. Validity was excellent for step count (ICC = 0.97, p < 0.001) and fair for fitness (ICC = 0.47, p < 0.001). We found excellent test-retest reliability for step count (ICC = 0.91, p < 0.001) and physical fitness (ICC = 0.88, p < 0.001).ConclusionsThis study showed that objective smartphone measurements of step count in clinical practice are feasible, valid and reliable. These findings indicate that the use of smartphones to objectively assess physical activity in clinical cancer practice is promising and may be used to select patients for treatment and study participation, to monitor patients during treatment and to guide treatment decisions.
Project description:Study designCross-sectional reliability and validity study.Purpose1. To determine intrarater, interrater and inter instrument reliabilities and validity of two digital electro goniometry to measure active wrist/finger range of motions (ROMs) in patients with limited motion. 2. To determine intrarater and interrater reliabilities of digital goniometry to measure torques of PIP passive flexion of the index finger in patients with limited motion.MethodsThe study was designed in a randomized block plan on 44 patients (24 women, 20 men) with limited wrist or hand motions. Two experienced raters measured active wrist ROMs, and active and passive index PIP flexion using two digital goniometers. All measures were repeated by one rater 2-5 days after the initial measurements. The reliability measures were analyzed using Intraclass Correlation Coefficients (ICCs) and the construct validity was determined by correlation coefficients analysis between sub measures of scores; patient rated pain and function (PRWE) and quick Disabilities of the Arm, Shoulder and Hand (quick DASH) scores.ResultsThe intrarater, interrater and inter instrument reliabilities were high in most ROM measures (range 0.64-0.97) for both types of electro-goniometers. The 95% limit of agreements and Bland and Altman plots did not show progressive changes. There was a significant difference in force application between the raters when performing passive ROM measures for PIP index, but the same rater produced consistent force. Most of the NK and J-Tech ROM measures were moderately correlated with the patient rated pain and function scores (range 0.32-0.63).
Project description:This study aimed to assess the validity and reliability of the three-dimensional joint kinematic outcomes obtained by the inertial measurement units (IMUs) for runners with rearfoot strike pattern (RFS) and non-rearfoot strike pattern (NRFS). The IMUs system and optical motion capture system were used to simultaneous collect 3D kinematic of lower extremity joint data from participants running at 12 km/h. The joint angle waveforms showed a high correlation between the two systems after the offset correction in the sagittal plane (NRFS: coefficient of multiple correlation (CMC) = 0.924–0.968, root mean square error (RMSE) = 4.6°–13.7°; RFS: CMC = 0.930–0.965, RMSE = 3.1°–7.7°), but revealed high variability in the frontal and transverse planes (NRFS: CMC = 0.924–0.968, RMSE = 4.6°–13.7°; RFS: CMC = 0.930–0.965, RMSE = 3.1°–7.7°). The between-rater and between-day reliability were shown to be very good to excellent in the sagittal plane (between-rater: NRFS: CMC = 0.967–0.975, RMSE = 1.9°–2.9°, RFS: CMC = 0.922–0.989, RMSE = 1.0°–2.5°; between-day: NRFS: CMC = 0.950–0.978, RMSE = 1.6°–2.7°, RFS: CMC = 0.920–0.989, RMSE = 1.7°–2.2°), whereas the reliability was weak to very good (between-rater: NRFS: CMC = 0.480–0.947, RMSE = 1.1°–2.7°, RFS: CMC = 0.646–0.873, RMSE = 0.7°–2.4°; between-day: NRFS: CMC = 0.666–0.867, RMSE = 0.7°–2.8°, RFS: CMC = 0.321–0.805, RMSE = 0.9°–5.0°) in the frontal and transverse planes across all joints in both types of runners. The IMUs system was a feasible tool for measuring lower extremity joint kinematics in the sagittal plane during running, especially for RFS runners. However, the joint kinematics data in frontal and transverse planes derived by the IMUs system need to be used with caution.
Project description:The number of (TTAGGG)n repeats at the ends of chromosomes is highly variable between individual chromosomes, between different cells and between species. Progressive loss of telomere repeats limits the proliferation of pre-malignant human cells but also contributes to aging by inducing apoptosis and senescence in normal cells. Despite enormous progress in understanding distinct pathways that result in loss and gain of telomeric DNA in different cell types, many questions remain. Further studies are needed to delineate the role of damage to telomeric DNA, replication errors, chromatin structure, liquid-liquid phase transition, telomeric transcripts (TERRA) and secondary DNA structures such as guanine quadruplex structures, R-loops and T-loops in inducing gains and losses of telomere repeats in different cell types. Limitations of current telomere length measurements techniques and differences in telomere biology between species and different cell types complicate generalizations about the role of telomeres in aging and cancer. Here some of the factors regulating the telomere length in embryonic and adult cells in mammals are discussed from a mechanistic and evolutionary perspective.