Unknown

Dataset Information

0

Modified sewing machine technique for iridodialysis repair, intraocular lens relocation, iris coloboma repair, Cionni ring fixation, and scleral-fixated intraocular lens.


ABSTRACT: The purpose of this study is to report the modification of sewing machine technique for iris dialysis repair (MSMT) and its usefulness in managing other conditions such as intraocular lens (IOL) subluxation, iris coloboma, Cionni ring for zonular dialysis, and for scleral-fixated IOL. MSMT was based on sewing machine principle using a prethreaded 26G/30G needle with prolene suture for minimally invasive iris dialysis repair in a closed chamber manner. So far, eight patients (trauma - 3, surgical complication - 5) underwent this procedure. This technique is further modified to extend its use for IOL relocation - 2, iris coloboma repair - 3, and Cionni ring fixation for zonular dialysis - 2, SFIOL - 5 patients. All 20 patients had good visual recovery and cosmetic outcome with minimal morbidity. To conclude, MSMT offers cost -effective, minimally invasive, easy to learn procedure with a potential to tackle several problems related with cataract surgery and iris defects, which even an average cataract surgeon can learn to perform when required. Further comparative studies with conventional techniques with large sample size are required to standardize this procedure.

SUBMITTER: Ravi Kumar KV 

PROVIDER: S-EPMC6080449 | biostudies-literature | 2018 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Modified sewing machine technique for iridodialysis repair, intraocular lens relocation, iris coloboma repair, Cionni ring fixation, and scleral-fixated intraocular lens.

Ravi Kumar Karamsetty Venkata KV  

Indian journal of ophthalmology 20180801 8


The purpose of this study is to report the modification of sewing machine technique for iris dialysis repair (MSMT) and its usefulness in managing other conditions such as intraocular lens (IOL) subluxation, iris coloboma, Cionni ring for zonular dialysis, and for scleral-fixated IOL. MSMT was based on sewing machine principle using a prethreaded 26G/30G needle with prolene suture for minimally invasive iris dialysis repair in a closed chamber manner. So far, eight patients (trauma - 3, surgical  ...[more]

Similar Datasets

| S-EPMC10808084 | biostudies-literature
| S-EPMC7774126 | biostudies-literature
| S-EPMC6836613 | biostudies-literature
| S-EPMC6056155 | biostudies-literature
| S-EPMC5665580 | biostudies-literature
| S-EPMC4185163 | biostudies-literature
| S-EPMC8161112 | biostudies-literature
| S-EPMC9263869 | biostudies-literature
| S-EPMC10433584 | biostudies-literature
| S-EPMC6113843 | biostudies-literature