Unknown

Dataset Information

0

Corrosion-resistant systems of formate packer fluid for G3/N80/TP110SS pipes at high temperature, high pressure and high H2S/CO2 ratios.


ABSTRACT: A series of corrosion problems caused by high-temperature, high-pressure and high-acid gas environments has been an issue in oil and gas production for a long time. During the development of a high-acid gas field, the petroleum pipe is subjected to many aspects of corrosion, and the corrosion mechanism is complicated by the condition of the coexistence of H2S/CO2. Based on the study of the corrosion problem associated with the formate packer fluid in Southwest China, three kinds of steels were studied for corrosion prevention in the alloy G3/N80 steel/TP110SS steel. The study shows that the corrosion rate of the formate packer fluid is low, but corrosion is severe in environments characterized by high temperatures, high pressures and high-acid gas contents. Based on the consideration of cost and the difficulty of realization, an anti-corrosion system was constructed based on the existing packer fluid, mainly through the introduction of a variety of anti-corrosion additives. Through the selection of various additives and corrosion experiments, a corrosion protection system of formate packer fluid was developed. Corrosion tests show that the corrosion rate of the system must be less than 0.076?mm?yr-1 to achieve the purpose of corrosion protection. The formate packer fluid with corrosion protection can meet the needs of the current application.

SUBMITTER: Xu P 

PROVIDER: S-EPMC6083718 | biostudies-literature | 2018 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Corrosion-resistant systems of formate packer fluid for G3/N80/TP110SS pipes at high temperature, high pressure and high H<sub>2</sub>S/CO<sub>2</sub> ratios.

Xu Peng P   Tao Zhengwu Z   Wang Zhihong Z  

Royal Society open science 20180725 7


A series of corrosion problems caused by high-temperature, high-pressure and high-acid gas environments has been an issue in oil and gas production for a long time. During the development of a high-acid gas field, the petroleum pipe is subjected to many aspects of corrosion, and the corrosion mechanism is complicated by the condition of the coexistence of H<sub>2</sub>S/CO<sub>2</sub>. Based on the study of the corrosion problem associated with the formate packer fluid in Southwest China, three  ...[more]

Similar Datasets

| S-EPMC5993159 | biostudies-literature
| S-EPMC6057943 | biostudies-literature
2015-04-15 | GSE65684 | GEO
| S-EPMC6502365 | biostudies-literature
| S-EPMC7796234 | biostudies-literature
| S-EPMC4579476 | biostudies-literature
2015-04-15 | E-GEOD-65684 | biostudies-arrayexpress