Unknown

Dataset Information

0

Computational simulation of aqueous humour dynamics in the presence of a posterior-chamber versus iris-fixed phakic intraocular lens.


ABSTRACT:

Purpose

To compare aqueous humour (AH) dynamics in the presence of a precrystalline (Implantable Collamer Lens®; ICL) or iris-fixed (Artiflex®) phakic intraocular lens (PIOL).

Methods

By computational fluid dynamics simulation, AH flow was modelled through a peripheral iridotomy (PI) or central lens hole (both 360 ?m) in the presence of an Artiflex or ICL lens, respectively. The impacts of AH flow were then determined in terms of wall shear stress (WSS) produced on the endothelium or crystalline lens. Effects were also modelled for different scenarios of pupil diameter (PD 3.5 or 5.5 mm), ICL vault (100, 350, 800 ?m) and number of Artiflex iridotomies (1 or 2) and location (12 or 6 o'clock).

Results

For a PD of 3.5 mm, AH volumes flowing from the posterior to the anterior chamber were 37.6% of total flow through the lens hole (ICL) and 84.2% through PI (Artiflex). For an enlarged PD (5.5 mm), corresponding values were 10.3% and 81.9% respectively, so PI constitutes a very efficient way of evacuating AH. Central endothelial WSS in Pa was lower for the large vault ICL and the Artiflex (1-03 and 1.1-03 respectively) compared to the PIOL-free eye (1.6-03). Crystalline lens WSS was highest for the lowest vault ICL (1-04).

Conclusions

AH flow varied according to the presence of a precrystalline or iris-fixed intraocular lens. Endothelial WSS was lower for an implanted ICL with large vault and Artiflex than in the PIOL-free eye, while highest crystalline WSS was recorded for the lowest vault ICL.

SUBMITTER: Fernandez-Vigo JI 

PROVIDER: S-EPMC6089426 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

Computational simulation of aqueous humour dynamics in the presence of a posterior-chamber versus iris-fixed phakic intraocular lens.

Fernández-Vigo José Ignacio JI   Marcos Alfonso C AC   Agujetas Rafael R   Montanero José María JM   Sánchez-Guillén Inés I   García-Feijóo Julián J   Pandal-Blanco Adrián A   Fernández-Vigo José Ángel JÁ   Macarro-Merino Ana A  

PloS one 20180813 8


<h4>Purpose</h4>To compare aqueous humour (AH) dynamics in the presence of a precrystalline (Implantable Collamer Lens®; ICL) or iris-fixed (Artiflex®) phakic intraocular lens (PIOL).<h4>Methods</h4>By computational fluid dynamics simulation, AH flow was modelled through a peripheral iridotomy (PI) or central lens hole (both 360 μm) in the presence of an Artiflex or ICL lens, respectively. The impacts of AH flow were then determined in terms of wall shear stress (WSS) produced on the endothelium  ...[more]

Similar Datasets

| S-EPMC7668562 | biostudies-literature
| S-EPMC7171658 | biostudies-literature
| S-EPMC5757340 | biostudies-literature
| S-EPMC5113895 | biostudies-literature
| S-EPMC4130551 | biostudies-other
| S-EPMC5511534 | biostudies-other
| S-EPMC8107636 | biostudies-literature
| S-EPMC6460692 | biostudies-literature
| S-EPMC6213707 | biostudies-literature
| S-EPMC8101126 | biostudies-literature