Objective assessment of a relative afferent pupillary defect by B-mode ultrasound.


ABSTRACT:

Purpose

To evaluate B-mode ultrasound as a novel method for objective and quantitative assessment of a relative afferent pupillary defect (RAPD) in a prospective case-control study.

Methods

Seventeen patients with unilateral optic neuropathy and a clinically detectable RAPD and 17 age and sex matched healthy controls were examined with B-mode ultrasound using an Esaote-Mylab25 system according to current guidelines for orbital insonation. The swinging flashlight test was performed during ultrasound assessment with a standardized light stimulus using a penlight.

Results

B-mode ultrasound RAPD examination was doable in approximately 5 minutes only and was well tolerated by all participants. Compared to the unaffected contralateral eyes, eyes with RAPD showed lower absolute constriction amplitude of the pupillary diameter (mean [SD] 0.8 [0.4] vs. 2.1 [0.4] mm; p = 0.009) and a longer pupillary constriction time after ipsilateral light stimulus (mean [SD] 1240 [180] vs. 710 [200] ms; p = 0.008). In eyes affected by RAPD, visual acuity correlated with the absolute constriction amplitude (r = 0.75, p = 0.001).

Conclusions

B-mode ultrasound enables fast, easy and objective quantification of a RAPD and can thus be applied in clinical practice to document a RAPD.

SUBMITTER: Schmidt FA 

PROVIDER: S-EPMC6110480 | biostudies-literature | 2018

REPOSITORIES: biostudies-literature

altmetric image

Publications

Objective assessment of a relative afferent pupillary defect by B-mode ultrasound.

Schmidt Felix A FA   Connolly Florian F   Maas Matthew B MB   Grittner Ulrike U   Harms Lutz L   Brandt Alexander A   Paul Friedemann F   Schreiber Stephan S   Ruprecht Klemens K  

PloS one 20180827 8


<h4>Purpose</h4>To evaluate B-mode ultrasound as a novel method for objective and quantitative assessment of a relative afferent pupillary defect (RAPD) in a prospective case-control study.<h4>Methods</h4>Seventeen patients with unilateral optic neuropathy and a clinically detectable RAPD and 17 age and sex matched healthy controls were examined with B-mode ultrasound using an Esaote-Mylab25 system according to current guidelines for orbital insonation. The swinging flashlight test was performed  ...[more]

Similar Datasets

| S-EPMC3907131 | biostudies-literature
| S-EPMC9135214 | biostudies-literature
| S-EPMC10309159 | biostudies-literature
| S-EPMC7223719 | biostudies-literature
| S-EPMC4737255 | biostudies-other
| S-EPMC5546069 | biostudies-other
| S-EPMC7943421 | biostudies-literature
| S-EPMC3743455 | biostudies-literature
| S-EPMC4151360 | biostudies-other
| S-EPMC7453675 | biostudies-literature